Literature DB >> 16827737

The effect of die spacer on retention and fitting of complete cast crowns.

Anna Belsuzarri Olivera1, Tetsuo Saito.   

Abstract

PURPOSE: This study evaluated the effect of die spacer on the fit and retention of complete cast crowns by using three different cements.
MATERIALS AND METHODS: Standardized full crown restoration preparations were completed on 99 extracted molar teeth, impressions were made with poly(vinyl siloxane), and stone dies were made. Dies were covered with four layers of die spacer using three techniques: (1) covering the occlusal and 1/3 of the axial surfaces, (2) covering the occlusal and 2/3 of the axial surfaces, and (3) covering the entire preparation except the apical 0.5 mm of the preparation. Complete metal crowns were cast using Pors-on 4 alloy. Crowns were then assigned to one of three luting agent groups: resin modified glass ionomer cement, resin cement, or zinc phosphate cement. The castings were placed on their respective teeth and the marginal opening was recorded by two methods: 72 specimens were examined before and after cementation using optical microscopy with 0.001 mm resolution, and 27 specimens were examined after cementation with scanning electron microscopy. After cementation, the teeth were thermocycled for 700 cycles between 5 degrees C and 55 degrees C. The tensile retentive strength was measured on a universal testing machine with a crosshead speed of 0.5 mm/min. The data obtained for the fitting were recorded in millimeters and the data for the tensile retentive strength were recorded in KgF. The statistical analysis was performed by analysis of variance and post hoc Tukey's test (p< 0.05).
RESULTS: Before cementation, better marginal fit was obtained when the die spacer covered all but the area 0.5 mm short of the margin of the preparation; however, after cementation, the resin modified glass ionomer cement group had the best fit with the same application of die spacer. Castings luted with resin cement required the greatest tensile force to produce cement failure.
CONCLUSIONS: Increasing the area of the die surface covered with spacer improved the fit of the cast restoration. After cementation, the resin modified glass ionomer showed better adaptation; however, the optical microscopy and scanning microscopy correlate well. Resin cement had the highest resistance to tensile forces.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16827737     DOI: 10.1111/j.1532-849X.2006.00113.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  8 in total

1.  Marginal discrepancy as affected by selective placement of die-spacer: an in vitro study.

Authors:  Priyam Aditya; V N V Madhav; S V Bhide; Amita Aditya
Journal:  J Indian Prosthodont Soc       Date:  2012-05-11

2.  Evaluation of the Luting Cement Space for Provisional Restoration by using Various Coats of Die Spacer Materials-An Invitro Study.

Authors:  Sandeep Chiramana; Krishna Chaitanya Siddineni; Ravi Rakesh Dev Jyothula; Phani Krishna Gade; Deepthi Bhupathi; Sudheer Kondaka; Zakir Hussain; Geetha Bhavani Paluri
Journal:  J Clin Diagn Res       Date:  2014-09-20

3.  Marginal Accuracy of Castings Produced with Different Investment Systems.

Authors:  R K Yadav
Journal:  Med J Armed Forces India       Date:  2011-07-21

4.  Effect of Abutment Height on Retention of Single Cement-retained, Wide- and Narrow-platform Implant-supported Restorations.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Sara Nuroloyuni; Sohleh Khodabakhsh; Mehran Bahrami; Reza Nahidi; Somaieh Zeighami
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2012-09-01

5.  Evaluation of marginal fit and internal adaptation of zirconia copings fabricated by two CAD - CAM systems: An in vitro study.

Authors:  Balaji N Rajan; Srinivasan Jayaraman; Baburajan Kandhasamy; Ilangkumaran Rajakumaran
Journal:  J Indian Prosthodont Soc       Date:  2015 Apr-Jun

6.  In vitro Evaluation of the Marginal Fit and Internal Adaptation of Zirconia and Lithium Disilicate Single Crowns: Micro-CT Comparison Between Different Manufacturing Procedures.

Authors:  Francesco Riccitiello; Massimo Amato; Renato Leone; Gianrico Spagnuolo; Roberto Sorrentino
Journal:  Open Dent J       Date:  2018-02-22

Review 7.  Marginal and internal adaptation of lithium disilicate partial restorations: A systematic review and meta-analysis.

Authors:  Natália Almeida Bastos; Sandro Basso Bitencourt; Renan Figueiredo Carneiro; Brunna Mota Ferrairo; Samira Sandy Ferreira Strelhow; Daniela Micheline Dos Santos; Juliana Fraga Soares Bombonatti
Journal:  J Indian Prosthodont Soc       Date:  2020-10-08

8.  Comparison of Retention and Seating of Implant-Supported Hard and Soft Metal Copings.

Authors:  Safoura Ghodsi; Anahita Fayyazi; Maryam Ghiasi; Ahmad Rohanian; Marzieh Alikhasi
Journal:  Front Dent       Date:  2020-10-26
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.