Literature DB >> 16826107

Uncemented HA-coated implant is the optimum fixation for TKA in the young patient.

Kjell G Nilsson1, Anders Henricson, Bo Norgren, Tore Dalén.   

Abstract

UNLABELLED: Fixation of the tibial component in total knee arthroplasty in younger patients remains controversial. We evaluate the results of three different types of fixation of the Profix total knee arthroplasty in a randomized controlled trial of 97 consecutive knees (85 patients) with osteoarthrosis or inflammatory arthritis with 2-year followup of all patients. We randomized patients to three different types of fixation of the tibial component: cemented, uncemented (HA coated) with screws, or uncemented (HA coated) without screws. We performed clinical evaluations and radiostereometric analysis at 6 weeks, and 3, 6, 12 and 24 months postoperatively. The knees in the uncemented groups migrated more than those in the cemented group during the first 3 months, but at 2 years we observed no differences. The uncemented implants displayed all migration within the first 3 months. The cemented implants did not stabilize but had continuously increasing migration during the followup. Cementless implants without screws did not migrate more than implants with screws and displayed similar pattern of migration, indicating screws do not improve fixation. Uncemented fixation using hydroxyapatite-coated implants without screws seems to be the best solution for the younger patient. LEVEL OF EVIDENCE: Therapeutic Level I. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16826107     DOI: 10.1097/01.blo.0000224003.33260.74

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  23 in total

Review 1.  Larger range of motion and increased return to activity, but higher revision rates following unicompartmental versus total knee arthroplasty in patients under 65: a systematic review.

Authors:  Laura J Kleeblad; Jelle P van der List; Hendrik A Zuiderbaan; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-11-28       Impact factor: 4.342

2.  Changes in bone mineral density of the proximal tibia after uncemented total knee arthroplasty. A prospective randomized study.

Authors:  Nikolaj Winther; Claus Jensen; Morten Petersen; Thomas Lind; Henrik Schrøder; Michael Petersen
Journal:  Int Orthop       Date:  2015-07-17       Impact factor: 3.075

3.  Similar survival between screw cementless and cemented tibial components in young patients with osteoarthritis.

Authors:  Alejandro Lizaur-Utrilla; Francisco A Miralles-Muñoz; Fernando A Lopez-Prats
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11-08       Impact factor: 4.342

4.  No difference in terms of radiostereometric analysis between fixed- and mobile-bearing total knee arthroplasty: a randomized, single-blind, controlled trial.

Authors:  M G M Schotanus; P Pilot; B L Kaptein; W F Draijer; P B J Tilman; R Vos; N P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-27       Impact factor: 4.342

5.  Good long-term results following cementless TKA with a titanium plasma coating.

Authors:  Theodore Bouras; Vasileios Bitas; Peter Fennema; Panagiotis Korovessis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-03       Impact factor: 4.342

6.  Uncemented or cemented femoral components work equally well in total knee arthroplasty.

Authors:  Anders Henricson; Radek Wojtowicz; Kjell G Nilsson; Sead Crnalic
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-25       Impact factor: 4.342

Review 7.  Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties.

Authors:  Bart G Pijls; Edward R Valstar; Klaas-Auke Nouta; Josepha Wm Plevier; Marta Fiocco; Saskia Middeldorp; Rob Ghh Nelissen
Journal:  Acta Orthop       Date:  2012-11-09       Impact factor: 3.717

8.  Trabecular metal tibia still stable at 5 years: an RSA study of 36 patients aged less than 60 years.

Authors:  Anders Henricson; Dan Rösmark; Kjell G Nilsson
Journal:  Acta Orthop       Date:  2013-05-13       Impact factor: 3.717

Review 9.  Hydroxyapatite (HA) coating appears to be of benefit for implant durability of tibial components in primary total knee arthroplasty.

Authors:  Jeffrey D Voigt; Michael Mosier
Journal:  Acta Orthop       Date:  2011-06-10       Impact factor: 3.717

10.  A perspective on robotic assistance for knee arthroplasty.

Authors:  Nathan A Netravali; Feimo Shen; Youngbae Park; William L Bargar
Journal:  Adv Orthop       Date:  2013-04-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.