Literature DB >> 16825136

Screening of obstructive and central apnoea/hypopnoea in children using variability: a preliminary study.

Jong Yong A Foo1, Andrew P Bradley, Stephen J Wilson, Gordon R Williams, Carolyn Dakin, David M Cooper.   

Abstract

AIM: Polysomnography (PSG) is the current standard protocol for sleep disordered breathing (SDB) investigation in children. Presently, there are limited reliable screening tests for both central (CE) and obstructive (OE) respiratory events. This study compared three indices, derived from pulse oximetry and electrocardiogram (ECG), with the PSG gold standard. These indices were heart rate (HR) variability, arterial blood oxygen de-saturation (SaO2) and pulse transit time (PTT).
METHODS: 15 children (12 male) from routine PSG studies were recruited (aged 3-14 years). The characteristics of the three indices were based on known criteria for respiratory events (RPE). Their estimation singly and in combination was evaluated with simultaneous scored PSG recordings.
RESULTS: 215 RPE and 215 tidal breathing events were analysed. For OE, the obtained sensitivity was HR (0.703), SaO2 (0.047), PTT (0.750), considering all three indices (0) and either of the indices (0.828) while specificity was (0.891), (0.938), (0.922), (0.953) and (0.859) respectively. For CE, the sensitivity was HR (0.715), SaO2 (0.278), PTT (0.662), considering all indices (0.040) and either of the indices (0.868) while specificity was (0.815), (0.954), (0.901), (0.960) and (0.762) accordingly.
CONCLUSIONS: Preliminary findings herein suggest that the later combination of these non-invasive indices to be a promising screening method of SDB in children.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16825136     DOI: 10.1080/08035250500477552

Source DB:  PubMed          Journal:  Acta Paediatr        ISSN: 0803-5253            Impact factor:   2.299


  6 in total

1.  Cardiovascular Consequences in Children with Obstructive Sleep Apnea: Is It Possible to Predict Them?

Authors:  Pablo E Brockmann
Journal:  Sleep       Date:  2015-09-01       Impact factor: 5.849

2.  Improving detection of obstructive sleep apnoea by overnight oximetry in children using pulse rate parameters.

Authors:  Dg Zuraini Sahadan; Margot J Davey; Rosemary S C Horne; Gillian M Nixon
Journal:  Sleep Breath       Date:  2015-03-05       Impact factor: 2.816

3.  At-home pulse oximetry in children undergoing adenotonsillectomy for obstructive sleep apnea.

Authors:  Martino Pavone; Nicola Ullmann; Elisabetta Verrillo; Giancarlo De Vincentiis; Emanuela Sitzia; Renato Cutrera
Journal:  Eur J Pediatr       Date:  2017-02-06       Impact factor: 3.183

Review 4.  Chemoreceptors, baroreceptors, and autonomic deregulation in children with obstructive sleep apnea.

Authors:  David Gozal; Fahed Hakim; Leila Kheirandish-Gozal
Journal:  Respir Physiol Neurobiol       Date:  2012-08-29       Impact factor: 1.931

5.  Sympathetic and catecholaminergic alterations in sleep apnea with particular emphasis on children.

Authors:  Fahed Hakim; David Gozal; Leila Kheirandish-Gozal
Journal:  Front Neurol       Date:  2012-01-30       Impact factor: 4.003

6.  Correlation between the severity of obstructive sleep apnea and heart rate variability indices.

Authors:  Doo-Heum Park; Chul-Jin Shin; Seok-Chan Hong; Jaehak Yu; Seung-Ho Ryu; Eui-Joong Kim; Hong-Beom Shin; Byoung-Hak Shin
Journal:  J Korean Med Sci       Date:  2008-04       Impact factor: 2.153

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.