| Literature DB >> 16822674 |
Dorota Kulikowska1, Ewa Klimiuk, A Drzewicki.
Abstract
The aim of this study was to estimate the BOD(5) and COD removal efficiency and biomass yield coefficient in sequencing batch reactors (SBR) treating landfill leachate. Experiments were carried out in four SBRs at HRT of 12, 6, 3 and 2d. Two series were performed. In series 1, the reactors were operated in a 24h cycle mode (anoxic 3h, aeration 18 h, settling 2.75 h, and discharge 0.25 h). In series 2, however, the anoxic phase was eliminated. In both series the BOD(5) removal efficiency was almost identical--over 98%. On shortening HRT from 12 to 2d, COD removal efficiency decreased from 83.1% to 76.7% (series 1). In series 2, efficiency ranged from 79.6% to 75.7%. In the reactors working with the anoxic phase the observed biomass yield coefficient (Y(obs)) was nearly constant (0.55-0.6 mg VSS/mg COD). Upon elimination of the anoxic phase, the Y(obs) was observed to decrease from 0.32 mg VSS/mg COD (HRT 2d) to 0.04 mg VSS/mg COD (HRT 12d).Entities:
Mesh:
Substances:
Year: 2006 PMID: 16822674 DOI: 10.1016/j.biortech.2006.05.021
Source DB: PubMed Journal: Bioresour Technol ISSN: 0960-8524 Impact factor: 9.642