Literature DB >> 16820803

The effects of temperature and light intensity on the polymerization shrinkage of light-cured composite filling materials.

Ahmed A Elhejazi1.   

Abstract

UNLABELLED: The aim of this study was to investigate the effect of light intensity on polymerization shrinkage of resin composites. The five materials tested were Lite-Fil (A) (LFA), Lite-Fil (P) (LFP), Z100, Palfique, (PAL) and Tetric (TRC). Two types of measurements were made to determine the effects of environmental temperature and light intensity. Results were analyzed by two-way analysis of variance (ANOVA) and Newman-Keuls procedure at (P<0.05). The changes in temperature and/or light intensity strongly affected composite shrinkage. The amount of shrinkage for LFP at 100% light intensity in room temperature (23 degrees C) was 1.26% and increased up to 2.29% at 60 degrees C. By raising the temperature to 37 degrees C and dropping the light intensity to 42% (459 mW/cm2), the amount of polymerization shrinkage was similar to that with full light intensity, and statistically there were no significant differences between 37 degrees C, 45 degrees C, and 60 degrees C. Lower temperatures and lower light intensities produce lower values of shrinkage. However, if the light intensity is below 28%, higher temperatures (60 degrees C) must be applied to obtain a comparable amount of shrinkage. CLINICAL RELEVANCE: Pre-heating composite resin materials at body temperature (37 degrees C) is likely to improve physical properties and compensate any drop of light intensity.

Mesh:

Substances:

Year:  2006        PMID: 16820803

Source DB:  PubMed          Journal:  J Contemp Dent Pract        ISSN: 1526-3711


  4 in total

1.  The effect of composite resin preheating on marginal adaptation of class II restorations.

Authors:  Farideh Darabi; Reza Tayefeh-Davalloo; Seyedeh-Maryam Tavangar; Fereshteh Naser-Alavi; Mozhdeh Boorboo-Shirazi
Journal:  J Clin Exp Dent       Date:  2020-07-01

2.  Effect of the different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface hardness, and depth of cure of bulk fill composite.

Authors:  Dabburi Tirumala; Tammineedi Sravanthi; Bolla Nagesh; Chukka Ram Sunil; Basam Ram Chowdary; Polineni Swapnika
Journal:  Med Pharm Rep       Date:  2022-04-28

3.  Comparison of variation in the light curing cycle with a time gap and its effect on polymerization shrinkage, degree of conversion and microhardness of a nanohybrid composite.

Authors:  Arunajatesan Subbiya; Newbegin Selvakumar Gold Pearlin Mary; Malathi Suresh; Paramasivam Vivekanandhan; Malarvizhi Dhakshinamoorthy; Vridhachalam Ganapathy Sukumaran
Journal:  J Conserv Dent       Date:  2015 Mar-Apr

4.  The effect of repeated preheating of dimethacrylate and silorane-based composite resins on marginal gap of class V restorations.

Authors:  Parnian Alizadeh Oskoee; Fatemeh Pournaghi Azar; Elmira Jafari Navimipour; Mohammad Esmaeel Ebrahimi Chaharom; Fereshteh Naser Alavi; Ashkan Salari
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-03-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.