BACKGROUND: Ischemic mitral regurgitation (IMR) is associated with asymmetric changes in annular and ventricular geometry. Surgical repair with standard symmetric annuloplasty rings results in a high incidence of residual or recurrent mitral regurgitation (MR). The Carpentier-McCarthy-Adams (CMA) IMR ETlogix annuloplasty ring is the first remodeling ring specifically designed to treat asymmetric leaflet tethering and annular dilatation. We used quantitative 2-dimensional echo to examine early results of mitral valve (MV) repair with the CMA IMR ETlogix annuloplasty ring in patients with IMR. METHODS AND RESULTS: Fifty-nine patients (aged 68+/-12 years) with grade > or = 2+ IMR (graded on a scale of 0 to 4+) underwent MV repair with the CMA IMR ETlogix annuloplasty ring. We assessed the mitral annular diameter (MAD), tethering area (TA), and tenting height (TH) of the MV in 4-chamber, 2-chamber, and long axis views at mid-systole before and 3 to 10 days after surgery. After surgery, 57 of 59 (97%) patients had grade 0 or 1+ MR, whereas 2 patients had 2+ MR. MV repair with the CMA IMR ETlogix ring significantly reduced MAD, TA, and TH (P<0.001, for all 3 echo views), particularly in the long axis and 4-chamber views. CONCLUSIONS: Surgical repair of IMR with the novel asymmetric CMA IMR ETlogix annuloplasty ring provided excellent early results with effective reduction of MR, MAD, and leaflet tethering. This novel etiology-specific strategy may result in improved outcomes in IMR patients.
BACKGROUND:Ischemic mitral regurgitation (IMR) is associated with asymmetric changes in annular and ventricular geometry. Surgical repair with standard symmetric annuloplasty rings results in a high incidence of residual or recurrent mitral regurgitation (MR). The Carpentier-McCarthy-Adams (CMA) IMR ETlogix annuloplasty ring is the first remodeling ring specifically designed to treat asymmetric leaflet tethering and annular dilatation. We used quantitative 2-dimensional echo to examine early results of mitral valve (MV) repair with the CMA IMR ETlogix annuloplasty ring in patients with IMR. METHODS AND RESULTS: Fifty-nine patients (aged 68+/-12 years) with grade > or = 2+ IMR (graded on a scale of 0 to 4+) underwent MV repair with the CMA IMR ETlogix annuloplasty ring. We assessed the mitral annular diameter (MAD), tethering area (TA), and tenting height (TH) of the MV in 4-chamber, 2-chamber, and long axis views at mid-systole before and 3 to 10 days after surgery. After surgery, 57 of 59 (97%) patients had grade 0 or 1+ MR, whereas 2 patients had 2+ MR. MV repair with the CMA IMR ETlogix ring significantly reduced MAD, TA, and TH (P<0.001, for all 3 echo views), particularly in the long axis and 4-chamber views. CONCLUSIONS: Surgical repair of IMR with the novel asymmetric CMA IMR ETlogix annuloplasty ring provided excellent early results with effective reduction of MR, MAD, and leaflet tethering. This novel etiology-specific strategy may result in improved outcomes in IMR patients.
Authors: Simon H Sündermann; Michael Gessat; Nikola Cesarovic; Thomas Frauenfelder; Patric Biaggi; Dominique Bettex; Volkmar Falk; Stephan Jacobs Journal: Interact Cardiovasc Thorac Surg Date: 2013-01-03
Authors: Liang Ge; William G Morrel; Alison Ward; Rakesh Mishra; Zhihong Zhang; Julius M Guccione; Eugene A Grossi; Mark B Ratcliffe Journal: Ann Thorac Surg Date: 2014-03-13 Impact factor: 4.330
Authors: Vincent M Wong; Jonathan F Wenk; Zhihong Zhang; Guangming Cheng; Gabriel Acevedo-Bolton; Mike Burger; David A Saloner; Arthur W Wallace; Julius M Guccione; Mark B Ratcliffe; Liang Ge Journal: Ann Thorac Surg Date: 2012-01-15 Impact factor: 4.330
Authors: Wolfgang Bothe; Manuel K Rausch; John-Peder Escobar Kvitting; Dominique K Echtner; Mario Walther; Neil B Ingels; Ellen Kuhl; D Craig Miller Journal: Circulation Date: 2012-09-11 Impact factor: 29.690