Reliability of respiratory tidal volume estimation by means of ambulatory inductive plethysmography.

Paul Grossman1, Monika Spoerle, Frank H Wilhelm.   

Abstract

Ambulatory monitoring of ventilatory parameters in everyday life, field research and clinical situations may offer new insights into respiratory functioning in health and disease. Recent technological advances that employ ambulatory inductive plethysmography could make monitoring of respiration outside the clinic and laboratory feasible. Inductive plethysmography provides a method for nonintrusive assessment of both timing (e.g. respiration rate) and volumetric parameters (e.g. tidal volume and minute ventilation), by which tidal volume is initially calibrated to direct measures of volume. Estimates of tidal volume assessed by this technique have been validated in laboratory investigations, usually examining within-individual relations to direct measures over a large range of tidal volume variation. However, the reliability of individual differences in tidal volume or other breathing parameters has not been tested under naturalistic measurement conditions using inductive plethysmography. We examined the test-retest reliability of respiration rate, tidal volume and other volumetric parameters of breathing over a period of six weeks of repeated measurements during baseline conditions and breathing exercises with 16 healthy freely moving volunteers in a Yoga course. Reliability of measurement was evaluated by calculating the average week-to-week between-subject correlation coefficients for each physiological measure. Additionally because body-mass index has been previously positively correlated to tidal volume, we also assessed this relationship as an external criterion of validity of tidal volume estimation. Regarding the latter, similar correlations to those previous studies were found (r = 0.6). Furthermore, reliability estimates were high and consistent across respiratory measures (typically r's = 0.7-0.8). These results suggest the validity of ambulatory inductive plethysmographic measurement of respiration, at least under relatively sedentary conditions. Findings also point to the stability of individual differences in respiratory parameters over consecutive weeks.

Mesh:

Year:  2006        PMID: 16817607

Source DB:  PubMed          Journal:  Biomed Sci Instrum        ISSN: 0067-8856


  5 in total

1.  Bioharness(™) Multivariable Monitoring Device: Part. II: Reliability.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

2.  Field based reliability and validity of the bioharness™ multivariable monitoring device.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew C S Mitchell; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

3.  Tidal volume estimation using the blanket fractal dimension of the tracheal sounds acquired by smartphone.

Authors:  Natasa Reljin; Bersain A Reyes; Ki H Chon
Journal:  Sensors (Basel)       Date:  2015-04-27       Impact factor: 3.576

4.  Separation of respiratory influences from the tachogram: a methodological evaluation.

Authors:  Devy Widjaja; Alexander Caicedo; Elke Vlemincx; Ilse Van Diest; Sabine Van Huffel
Journal:  PLoS One       Date:  2014-07-08       Impact factor: 3.240

5.  Employing an Incentive Spirometer to Calibrate Tidal Volumes Estimated from a Smartphone Camera.

Authors:  Bersain A Reyes; Natasa Reljin; Youngsun Kong; Yunyoung Nam; Sangho Ha; Ki H Chon
Journal:  Sensors (Basel)       Date:  2016-03-18       Impact factor: 3.576