Literature DB >> 16809136

An amperometric biosensor for uric acid determination prepared from uricase immobilized in polypyrrole film.

Servet Cete1, Ahmet Yaşar, Fatma Arslan.   

Abstract

In order to prepare a biosensor for the determination of uric acid, electropolymerization of pyrrole on Pt surface was carried out with an electrochemical cell containing pyrrole, ferrocene (as a electron mediator) and tetrabutylammonium tetrafluoroborat in acetonitrile by cyclic voltammetry between 0.0 and 1.0 V (vs. Ag/AgCl) at a scan rate of 50 mV/s upon Pt electrode. Uricase was immobilized by a glutaraldehyde/gelatine croslinking procedure on to polypyrrole film after the electropolymerization processes. The response of the biosensor against uric acid was measured after 330 seconds following the application of a constant potential of +0.7 V (vs. Ag/AgCl). The resulting biosensor exhibits excellent electrocatalysis for the uric acid. The amperometric determination is based on the electrochemical detection of H2O2, which is generated in enzymatic reaction of uric acid. The sensor responds to uric acid with a detection limit of 5.0 x 10(-7) M. The sensor remains relatively stable for 5 weeks. Interference effect were investigated on the amperometric response of the biosensor. Determination of uric acid was carried out in the biological fluids by biosensor.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16809136     DOI: 10.1080/10731190600684116

Source DB:  PubMed          Journal:  Artif Cells Blood Substit Immobil Biotechnol        ISSN: 1073-1199


  9 in total

Review 1.  Advances in the design of nanomaterial-based electrochemical affinity and enzymatic biosensors for metabolic biomarkers: A review.

Authors:  Leila Farzin; Mojtaba Shamsipur; Leila Samandari; Shahab Sheibani
Journal:  Mikrochim Acta       Date:  2018-05-02       Impact factor: 5.833

2.  Designed Mini Protein 20 Mimicking Uricase Encapsulated in ZIF-8 as Nanozyme Biosensor for Uric Acid Detection.

Authors:  Siti Fatimah Nur Abdul Aziz; Abu Bakar Salleh; Siti Efliza Ashari; Yahaya M Normi; Nor Azah Yusof; Shahrul Ainliah Alang Ahmad
Journal:  Nanomaterials (Basel)       Date:  2022-07-04       Impact factor: 5.719

Review 3.  Electrochemical Sensors for Clinic Analysis.

Authors:  You Wang; Hui Xu; Jianming Zhang; Guang Li
Journal:  Sensors (Basel)       Date:  2008-03-27       Impact factor: 3.576

4.  Preparation of a polypyrrole-polyvinylsulphonate composite film biosensor for determination of cholesterol based on entrapment of cholesterol oxidase.

Authors:  Fadime Yıldırımoğlu; Fatma Arslan; Servet Cete; Ahmet Yaşar
Journal:  Sensors (Basel)       Date:  2009-08-20       Impact factor: 3.576

Review 5.  BioMEMS -Advancing the Frontiers of Medicine.

Authors:  Teena James; Manu Sebastian Mannoor; Dentcho V Ivanov
Journal:  Sensors (Basel)       Date:  2008-09-26       Impact factor: 3.576

6.  An Amperometric Biosensor for Uric Acid Determination Prepared From Uricase Immobilized in Polyaniline-Polypyrrole Film.

Authors:  Fatma Arslan
Journal:  Sensors (Basel)       Date:  2008-09-04       Impact factor: 3.576

7.  Harnessing a previously unidentified capability of bacterial allosteric transcription factors for sensing diverse small molecules in vitro.

Authors:  Jiaqian Cao; Yongpeng Yao; Keqiang Fan; Gaoyi Tan; Wensheng Xiang; Xuekui Xia; Shanshan Li; Weishan Wang; Lixin Zhang
Journal:  Sci Adv       Date:  2018-11-28       Impact factor: 14.136

8.  Peroxidase-Like Behavior of Ni Thin Films Deposited by Glancing Angle Deposition for Enzyme-Free Uric Acid Sensing.

Authors:  Anuja Tripathi; Kenneth D Harris; Anastasia L Elias
Journal:  ACS Omega       Date:  2020-04-13

9.  Determination of uric acid level by polyaniline and poly (allylamine): Based biosensor.

Authors:  Nasrul Wathoni; Aliya Nur Hasanah; Dolih Gozali; Yeni Wahyuni; Lia Layusa Fauziah
Journal:  J Adv Pharm Technol Res       Date:  2014-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.