Literature DB >> 16808489

Label-free electrochemical detection of protein based on a ferrocene-bearing cationic polythiophene and aptamer.

Fabien Le Floch1, Hoang A Ho, Mario Leclerc.   

Abstract

Two label-free electrochemical methods for the detection of human alpha-thrombin using a water-soluble, ferrocene-functionalized polythiophene transducer and a single-stranded oligonucleotide aptamer probe are described. The first approach is a direct method in which the recorded current decreases upon addition of the targeted protein. The second one requires more steps and the additional utilization of PNA probes and nuclease enzyme. This indirect method leads to an increase of the electrical signal as a function of the concentration of human alpha-thrombin with a detection limit of 75 fmol.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16808489     DOI: 10.1021/ac0521955

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

1.  Calibration-Free Electrochemical Biosensors Supporting Accurate Molecular Measurements Directly in Undiluted Whole Blood.

Authors:  Hui Li; Philippe Dauphin-Ducharme; Gabriel Ortega; Kevin W Plaxco
Journal:  J Am Chem Soc       Date:  2017-08-02       Impact factor: 15.419

Review 2.  Functional nucleic acid sensors.

Authors:  Juewen Liu; Zehui Cao; Yi Lu
Journal:  Chem Rev       Date:  2009-05       Impact factor: 60.622

3.  Coffee ring aptasensor for rapid protein detection.

Authors:  Jessica T Wen; Chih-Ming Ho; Peter B Lillehoj
Journal:  Langmuir       Date:  2013-04-15       Impact factor: 3.882

Review 4.  Aptamers and their biological applications.

Authors:  Kyung-Mi Song; Seonghwan Lee; Changill Ban
Journal:  Sensors (Basel)       Date:  2012-01-09       Impact factor: 3.576

5.  Electrochemical DNA hybridization sensors based on conducting polymers.

Authors:  Md Mahbubur Rahman; Xiao-Bo Li; Nasrin Siraj Lopa; Sang Jung Ahn; Jae-Joon Lee
Journal:  Sensors (Basel)       Date:  2015-02-05       Impact factor: 3.576

Review 6.  Over-the-Counter Biosensors: Past, Present, and Future.

Authors:  Thomas Ming-Hung Lee
Journal:  Sensors (Basel)       Date:  2008-09-06       Impact factor: 3.576

7.  Vascular Endothelial Growth Factor (VEGF) Detection Using an Aptamer and PNA-Based Bound/Free Separation System.

Authors:  Chifuku Mita; Koichi Abe; Takahiro Fukaya; Kazunori Ikebukuro
Journal:  Materials (Basel)       Date:  2014-02-11       Impact factor: 3.623

8.  Structural characterization of the saxitoxin-targeting APTSTX1 aptamer using optical tweezers and molecular dynamics simulations.

Authors:  Nathalie Casanova-Morales; Nataniel L Figueroa; Karol Alfaro; Felipe Montenegro; Nelson P Barrera; J R Maze; Christian A M Wilson; Pablo Conejeros
Journal:  PLoS One       Date:  2019-11-07       Impact factor: 3.240

Review 9.  Using Aptamers as a Novel Method for Determining GnRH/LH Pulsatility.

Authors:  Chioma Izzi-Engbeaya; Ali Abbara; Anthony Cass; Waljit S Dhillo
Journal:  Int J Mol Sci       Date:  2020-10-07       Impact factor: 5.923

Review 10.  Analytical methods for microplastics in the environment: a review.

Authors:  Zike Huang; Bo Hu; Hui Wang
Journal:  Environ Chem Lett       Date:  2022-09-29       Impact factor: 13.615

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.