Literature DB >> 16808438

Characterization of a second-generation focal-plane camera coupled to an inductively coupled plasma Mattauch-Herzog geometry mass spectrograph.

Gregory D Schilling1, Francisco J Andrade, James H Barnes, Roger P Sperline, M Bonner Denton, Charles J Barinaga, David W Koppenaal, Gary M Hieftje.   

Abstract

A second-generation Faraday-strip array detector has been coupled to an inductively coupled plasma Mattauch-Herzog geometry mass spectrograph, thereby offering simultaneous acquisition of a range of mass-to-charge ratios. The second-generation device incorporates narrower, more closely spaced collectors than the earlier system. Furthermore, the new camera can acquire signal on all collectors at a frequency greater than 2 kHz and has the ability to independently adjust the gain level of each collector. Each collector can also be reset independently. With these improvements, limits of detection in the hundreds of picograms per liter for metals in solution have been obtained. Some additional features, such as a broader linear dynamic range (over 7 orders of magnitude), greater resolving power (up to 600), and improved isotope ratio accuracy were attained. In addition, isotope ratio precision as low as 0.018% RSD was achieved.

Year:  2006        PMID: 16808438     DOI: 10.1021/ac052026k

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  IonCCD detector for miniature sector-field mass spectrometer: investigation of peak shape and detector surface artifacts induced by keV ion detection.

Authors:  Omar Hadjar; Thomas Schlathölter; Stephen Davila; Shane A Catledge; Ken Kuhn; Scott Kassan; Gottfried Kibelka; Chad Cameron; Guido F Verbeck
Journal:  J Am Soc Mass Spectrom       Date:  2011-08-09       Impact factor: 3.109

2.  Distance-of-Flight Mass Spectrometry with IonCCD Detection and an Inductively Coupled Plasma Source.

Authors:  Elise A Dennis; Steven J Ray; Christie G Enke; Alexander W Gundlach-Graham; Charles J Barinaga; David W Koppenaal; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2015-11-09       Impact factor: 3.109

3.  Detection of positive and negative ions from a flowing atmospheric pressure afterglow using a Mattauch-Herzog mass spectrograph equipped with a Faraday-strip array detector.

Authors:  Gregory D Schilling; Jacob T Shelley; James H Barnes; Roger P Sperline; M Bonner Denton; Charles J Barinaga; David W Koppenaal; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2009-09-20       Impact factor: 3.109

4.  IonCCD™ for direct position-sensitive charged-particle detection: from electrons and keV ions to hyperthermal biomolecular ions.

Authors:  Omar Hadjar; Grant Johnson; Julia Laskin; Gottfried Kibelka; Scott Shill; Ken Kuhn; Chad Cameron; Scott Kassan
Journal:  J Am Soc Mass Spectrom       Date:  2011-02-08       Impact factor: 3.109

5.  How constant momentum acceleration decouples energy and space focusing in distance-of-flight and time-of-flight mass spectrometries.

Authors:  Elise A Dennis; Alexander W Gundlach-Graham; Christie G Enke; Steven J Ray; Anthony J Carado; Charles J Barinaga; David W Koppenaal; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2013-03-23       Impact factor: 3.109

6.  Distance-of-Flight Mass Spectrometry: What, Why, and How?

Authors:  Elise A Dennis; Alexander W Gundlach-Graham; Steven J Ray; Christie G Enke; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2016-08-25       Impact factor: 3.109

7.  Quantification of 71 detected elements from Li to U for aqueous samples by simultaneous-inductively coupled plasma-mass spectrometry.

Authors:  Melanie Bäuchle; Tina Lüdecke; Sasan Rabieh; Khemet Calnek; Timothy G Bromage
Journal:  RSC Adv       Date:  2018-11-19       Impact factor: 4.036

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.