Literature DB >> 16808435

Liver-specific functional studies in a microfluidic array of primary mammalian hepatocytes.

Bartholomew J Kane1, Michael J Zinner, Martin L Yarmush, Mehmet Toner.   

Abstract

Nearly half a billion dollars in resources are lost each time a drug candidate is withdrawn from the market by the Food and Drug Administration (FDA) for reasons of liver toxicity. The number of late-phase drug developmental failures due to liver toxicity could potentially be reduced through the use of hepatocyte-based systems capable of modeling the response of in vivo liver tissue to toxic insults. With this article, we report progress toward the goal of realizing an array of primary hepatocytes for use in high-throughput liver toxicity studies. Described herein is the development of a 64 (8 x 8) element array of microfluidic wells capable of supporting micropatterned primary rat hepatocytes in coculture with 3T3-J2 fibroblasts. Each of the wells within the array was continuously perfused with medium and oxygen in a nonaddressable format. The key features of the system design and fabrication are described, including the use of two microfluidic perfusion networks to provide the coculture with an independent and continuous supply of cell culture medium and oxygen. Also described are the fabrication techniques used to selectively pattern hepatocytes and 3T3-J2 fibroblasts within the wells of the array. The functional studies used to demonstrate the synthetic and metabolic capacity of the array are outlined in this article. These studies demonstrate that the hepatocytes contained within the array are capable of continuous, steady-state albumin synthesis (78.4 microg/day, sigma = 3.98 microg/day, N = 8) and urea production (109.8 microg/day, sigma = 11.9 microg/day, N = 8). In the final section of the article, these results are discussed as they relate to the final goal of this research effort, the development of an array of primary hepatocytes for use in physiologically relevant toxicology studies.

Entities:  

Mesh:

Year:  2006        PMID: 16808435     DOI: 10.1021/ac051856v

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  68 in total

1.  Adipocyte-derived basement membrane extract with biological activity: applications in hepatocyte functional augmentation in vitro.

Authors:  Nripen S Sharma; Deepak Nagrath; Martin L Yarmush
Journal:  FASEB J       Date:  2010-03-16       Impact factor: 5.191

2.  Microfluidic droplet sorting with a high frequency ultrasound beam.

Authors:  Changyang Lee; Jungwoo Lee; Hyung Ham Kim; Shia-Yen Teh; Abraham Lee; In-Young Chung; Jae Yeong Park; K Kirk Shung
Journal:  Lab Chip       Date:  2012-05-29       Impact factor: 6.799

3.  A versatile valve-enabled microfluidic cell co-culture platform and demonstration of its applications to neurobiology and cancer biology.

Authors:  Yandong Gao; Devi Majumdar; Bojana Jovanovic; Candice Shaifer; P Charles Lin; Andries Zijlstra; Donna J Webb; Deyu Li
Journal:  Biomed Microdevices       Date:  2011-06       Impact factor: 2.838

4.  Culture of HepG2 liver cells on three dimensional polystyrene scaffolds enhances cell structure and function during toxicological challenge.

Authors:  Maria Bokhari; Ross J Carnachan; Neil R Cameron; Stefan A Przyborski
Journal:  J Anat       Date:  2007-08-15       Impact factor: 2.610

5.  High content cell screening in a microfluidic device.

Authors:  Raymond Cheong; Chiaochun Joanne Wang; Andre Levchenko
Journal:  Mol Cell Proteomics       Date:  2008-10-24       Impact factor: 5.911

6.  A microfluidic platform for real-time and in situ monitoring of virus infection process.

Authors:  Na Xu; Zhen-Feng Zhang; Li Wang; Bo Gao; Dai-Wen Pang; Han-Zhong Wang; Zhi-Ling Zhang
Journal:  Biomicrofluidics       Date:  2012-09-27       Impact factor: 2.800

7.  Microfabrication of human organs-on-chips.

Authors:  Dongeun Huh; Hyun Jung Kim; Jacob P Fraser; Daniel E Shea; Mohammed Khan; Anthony Bahinski; Geraldine A Hamilton; Donald E Ingber
Journal:  Nat Protoc       Date:  2013-10-10       Impact factor: 13.491

8.  Long-term flow through human intestinal organoids with the gut organoid flow chip (GOFlowChip).

Authors:  Barkan Sidar; Brittany R Jenkins; Sha Huang; Jason R Spence; Seth T Walk; James N Wilking
Journal:  Lab Chip       Date:  2019-10-09       Impact factor: 6.799

9.  Dynamic interplay of flow and collagen stabilizes primary hepatocytes culture in a microfluidic platform.

Authors:  Manjunath Hegde; Rohit Jindal; Abhinav Bhushan; Shyam Sundhar Bale; William J McCarty; Inna Golberg; O Berk Usta; Martin L Yarmush
Journal:  Lab Chip       Date:  2014-04-28       Impact factor: 6.799

10.  A novel ultrathin collagen nanolayer assembly for 3-D microtissue engineering: Layer-by-layer collagen deposition for long-term stable microfluidic hepatocyte culture.

Authors:  William J McCarty; O Berk Usta; Martha Luitje; Shyam Sundhar Bale; Abhinav Bhushan; Manjunath Hegde; Inna Golberg; Rohit Jindal; Martin L Yarmush
Journal:  Technology (Singap World Sci)       Date:  2014-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.