Literature DB >> 16808077

Validation of the soft tissue restraints in a force-controlled knee simulator.

M van Houtem1, R Clough, A Khan, M Harrison, G W Blunn.   

Abstract

In vitro testing of total knee replacements (TKRs) is important both at the design stage and after the production of the final components. It can predict long-term in vivo wear of TKRs. The two philosophies for knee testing are to drive the motion by displacement or to drive the motion by force. Both methods have advantages and disadvantages. For force control an accurate simulation of soft tissue restraints is required. This study was devised to assess the accuracy of the soft tissue restraints of the force-controlled Stanmore knee simulator in simulating the restraining forces of the anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL). In order to do this, human cadaver knee joints were subjected to the ISO Standard Walking Cycle. The resulting kinematics were monitored when the soft tissue structures were intact, when the ACL and PCL were resected, and when they were simulated by springs positioned anteriorly and posteriorly. The stiffness of the springs was determined from the literature. Two different stiffnesses of springs were used which were 7.24 N/mm (designated as soft springs) and 33.8 N/mm (designated as hard springs). All the intact knees showed displacements that were within the range of the machine. Cutting the ACL and PCL resulted in anterior and posterior motion and internal external rotation that were significantly greater than the intact knee. Results showed that when the ACL and PCL were cut hard springs positioned anterior and posterior to the knee returned the knee to near normal anterior-posterior (AP) motion. Using hard springs in the posterior position in any condition reduced rotational displacements. Therefore using springs in a force-controlled simulator is a compromise. More accuracy may be obtained using springs that are of intermediate stiffness.

Entities:  

Mesh:

Year:  2006        PMID: 16808077     DOI: 10.1243/09544119JEIM57

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  5 in total

1.  Changes in dynamic medial tibiofemoral contact mechanics and kinematics after injury of the anterior cruciate ligament: a cadaveric model.

Authors:  Asheesh Bedi; Tony Chen; Thomas J Santner; Saadiq El-Amin; Natalie H Kelly; Russell F Warren; Suzanne A Maher
Journal:  Proc Inst Mech Eng H       Date:  2013-06-26       Impact factor: 1.617

2.  Bone Plug Versus Suture-Only Fixation of Meniscal Grafts: Effect on Joint Contact Mechanics During Simulated Gait.

Authors:  Hongsheng Wang; Albert O Gee; Ian D Hutchinson; Kirsten Stoner; Russell F Warren; Tony O Chen; Suzanne A Maher
Journal:  Am J Sports Med       Date:  2014-04-28       Impact factor: 6.202

3.  In-vivo kinematics of knee prostheses patients during level walking compared with the ISO force-controlled simulator standard.

Authors:  V Ngai; T Schwenke; M A Wimmer
Journal:  Proc Inst Mech Eng H       Date:  2009-10       Impact factor: 1.617

4.  Development of a pre-clinical experimental simulation model of the natural porcine knee with appropriate ligamentous constraints.

Authors:  Aiqin Liu; Eileen Ingham; John Fisher; Louise M Jennings
Journal:  PLoS One       Date:  2019-05-14       Impact factor: 3.240

Review 5.  Influence of Menisci on Tibiofemoral Contact Mechanics in Human Knees: A Systematic Review.

Authors:  Matthias Sukopp; Florian Schall; Steffen P Hacker; Anita Ignatius; Lutz Dürselen; Andreas M Seitz
Journal:  Front Bioeng Biotechnol       Date:  2021-12-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.