Literature DB >> 16807812

Evaluation of blood access dysfunction based on a wavelet transform analysis of shunt murmurs.

Toshio Sato1, Kiichi Tsuji, Norimichi Kawashima, Tetsuzo Agishi, Hiroshi Toma.   

Abstract

We investigated shunt murmurs based on wavelet transform analysis as a new method for assessing vascular access function. In the present study, in patients with venous stenosis near an arteriovenous fistula (A-V fistula), a sensor was placed at different positions around the stenosis and shunt murmur signals obtained using a measurement system were subjected to time-frequency analysis based on wavelet transforms. The shunt murmurs obtained from the stenotic region closely represented some features of murmurs that are often referred to as "high-pitch" murmurs in the clinical setting. In contrast, shunt murmurs obtained about 5 cm downstream of the stenotic region closely represented some features of murmurs that are often referred to as "low-pitch" murmurs in the clinical setting. Furthermore, with the aim of extending the lifespan of arteriovenous grafts (A-V grafts) by detecting and treating stenotic lesions before the A-V graft becomes occluded, we evaluated the possibility of utilizing the present shunt murmur analysis for monitoring stenosis in such A-V grafts. When shunt murmurs from patients with A-V grafts were analyzed, the results suggested that the blood flow through the venous anastomosis of the graft was the most turbulent. This present method whereby blood flow in an A-V fistula is assessed based on the frequency distribution on a time-frequency plane by wavelet transform analysis is advantageous because findings are not markedly affected by sensor attachment. Furthermore, because the sensor is attached using an adhesive collar, measurements can be taken over a short period of time before each dialysis session.

Entities:  

Mesh:

Year:  2006        PMID: 16807812     DOI: 10.1007/s10047-005-0327-7

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  13 in total

1.  Endovascular management of thrombosed dialysis access grafts.

Authors:  G A Beathard; W A Marston
Journal:  Am J Kidney Dis       Date:  1998-07       Impact factor: 8.860

2.  NKF-DOQI clinical practice guidelines for vascular access. National Kidney Foundation-Dialysis Outcomes Quality Initiative.

Authors: 
Journal:  Am J Kidney Dis       Date:  1997-10       Impact factor: 8.860

3.  Effects of age and diabetes on blood flow rate and primary outcome of newly created hemodialysis arteriovenous fistulas.

Authors:  S L Lin; C H Huang; H S Chen; W A Hsu; C J Yen; T S Yen
Journal:  Am J Nephrol       Date:  1998       Impact factor: 3.754

4.  Factors associated with early failure of arteriovenous fistulae for haemodialysis access.

Authors:  V Wong; R Ward; J Taylor; S Selvakumar; T V How; A Bakran
Journal:  Eur J Vasc Endovasc Surg       Date:  1996-08       Impact factor: 7.069

5.  Angiography of upper extremity access fistulas for dialysis.

Authors:  S Glanz; B Bashist; D H Gordon; K Butt; R Adamsons
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

6.  Vascular access for hemodialysis. Patency rates and results of revision.

Authors:  S B Palder; R L Kirkman; A D Whittemore; R M Hakim; J M Lazarus; N L Tilney
Journal:  Ann Surg       Date:  1985-08       Impact factor: 12.969

Review 7.  The role of fluid mechanics in the localization and detection of atherosclerosis.

Authors:  D P Giddens; C K Zarins; S Glagov
Journal:  J Biomech Eng       Date:  1993-11       Impact factor: 2.097

8.  Increased blood flow inhibits neointimal hyperplasia in endothelialized vascular grafts.

Authors:  T R Kohler; T R Kirkman; L W Kraiss; B K Zierler; A W Clowes
Journal:  Circ Res       Date:  1991-12       Impact factor: 17.367

9.  Complications from permanent hemodialysis vascular access.

Authors:  G B Zibari; M S Rohr; M D Landreneau; R M Bridges; G A DeVault; F H Petty; K J Costley; S T Brown; J C McDonald
Journal:  Surgery       Date:  1988-10       Impact factor: 3.982

10.  Wavelet processing of systolic murmurs to assist with clinical diagnosis of heart disease.

Authors:  C Scott Hayek; W Reid Thompson; Charles Tuchinda; Richard A Wojcik; Joseph S Lombardo
Journal:  Biomed Instrum Technol       Date:  2003 Jul-Aug
View more
  4 in total

1.  Journal of Artificial Organs 2006: the year in review.

Authors:  Y Sawa; T Horiuchi; A Kishida; T Masuzawa; M Nishimura; E Tatsumi; Y Tomizawa; H Watanabe
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

2.  Flexible, Skin Coupled Microphone Array for Point of Care Vascular Access Monitoring.

Authors:  Binit Panda; Soumyajit Mandal; Steve J A Majerus
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-10-18       Impact factor: 3.833

3.  Quantification and Visualization of Reliable Hemodynamics Evaluation Based on Non-Contact Arteriovenous Fistula Measurement.

Authors:  Rumi Iwai; Takunori Shimazaki; Yoshifumi Kawakubo; Kei Fukami; Shingo Ata; Takeshi Yokoyama; Takashi Hitosugi; Aki Otsuka; Hiroyuki Hayashi; Masanobu Tsurumoto; Reiko Yokoyama; Tetsuya Yoshida; Shinya Hirono; Daisuke Anzai
Journal:  Sensors (Basel)       Date:  2022-04-02       Impact factor: 3.576

4.  Feasibility of Deep Learning-Based Analysis of Auscultation for Screening Significant Stenosis of Native Arteriovenous Fistula for Hemodialysis Requiring Angioplasty.

Authors:  Jae Hyon Park; Insun Park; Kichang Han; Jongjin Yoon; Yongsik Sim; Soo Jin Kim; Jong Yun Won; Shina Lee; Joon Ho Kwon; Sungmo Moon; Gyoung Min Kim; Man-Deuk Kim
Journal:  Korean J Radiol       Date:  2022-10       Impact factor: 7.109

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.