Literature DB >> 16804594

A multifunctional micro-fluidic system for dielectrophoretic concentration coupled with immuno-capture of low numbers of Listeria monocytogenes.

Liju Yang1, Padmapriya P Banada, Mohammad R Chatni, Kwan Seop Lim, Arun K Bhunia, Michael Ladisch, Rashid Bashir.   

Abstract

In this study, we demonstrated a micro-fluidic system with multiple functions, including concentration of bacteria using dielectrophoresis (DEP) and selective capture using antibody recognition, resulting in a high capture efficiency of bacterial cells. The device consisted of an array of oxide covered interdigitated electrodes on a flat silicon substrate and a approximately 16 microm high and approximately 260 microm wide micro-channel within a PDMS cover. For selective capture of Listeria monocytogenes from the samples, the channel surface was functionalized with a biotinylated BSA-streptavidin-biotinylated monoclonal antibody sandwich structure. Positive DEP (at 20 V(pp) and 1 MHz) was used to concentrate bacterial cells from the fluid flow. DEP could collect approximately 90% of the cells in a continuous flow at a flow rate of 0.2 microl min(-1) into the micro-channel with concentration factors between 10(2)-10(3), in sample volumes of 5-20 microl. A high flow rate of 0.6 microl min(-1) reduced the DEP capture efficiency to approximately 65%. Positive DEP attracts cells to the edges of the electrodes where the field gradient is the highest. Cells concentrated by DEP were captured by the antibodies immobilized on the channel surface with efficiencies of 18 to 27% with bacterial cell numbers ranging from 10(1) to 10(3) cells. It was found that DEP operation in our experiments did not cause any irreversible damage to bacterial cells in terms of cell viability. In addition, increased antigen expression (antigens to C11E9 monoclonal antibody) on cell membranes was observed following the exposure to DEP.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16804594     DOI: 10.1039/b607061m

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  23 in total

1.  'Living cantilever arrays' for characterization of mass of single live cells in fluids.

Authors:  Kidong Park; Jaesung Jang; Daniel Irimia; Jennifer Sturgis; James Lee; J Paul Robinson; Mehmet Toner; Rashid Bashir
Journal:  Lab Chip       Date:  2008-06-11       Impact factor: 6.799

Review 2.  Rare cell isolation and analysis in microfluidics.

Authors:  Yuchao Chen; Peng Li; Po-Hsun Huang; Yuliang Xie; John D Mai; Lin Wang; Nam-Trung Nguyen; Tony Jun Huang
Journal:  Lab Chip       Date:  2014-02-21       Impact factor: 6.799

Review 3.  Review: Microbial analysis in dielectrophoretic microfluidic systems.

Authors:  Renny E Fernandez; Ali Rohani; Vahid Farmehini; Nathan S Swami
Journal:  Anal Chim Acta       Date:  2017-03-06       Impact factor: 6.558

4.  A novel microbead-based microfluidic device for rapid bacterial identification and antibiotic susceptibility testing.

Authors:  J He; X Mu; Z Guo; H Hao; C Zhang; Z Zhao; Q Wang
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2014-07-05       Impact factor: 3.267

5.  Dielectrophoretic capture of low abundance cell population using thick electrodes.

Authors:  Julien Marchalot; Jean-François Chateaux; Magalie Faivre; Hichem C Mertani; Rosaria Ferrigno; Anne-Laure Deman
Journal:  Biomicrofluidics       Date:  2015-09-02       Impact factor: 2.800

6.  Impedimetric detection of bacteria by using a microfluidic chip and silver nanoparticle based signal enhancement.

Authors:  Renjie Wang; Yi Xu; Thomas Sors; Joseph Irudayaraj; Wen Ren; Rong Wang
Journal:  Mikrochim Acta       Date:  2018-02-19       Impact factor: 5.833

7.  Dielectrophoretic capture of E. coli cells at micropatterned nanoelectrode arrays.

Authors:  Lateef U Syed; Jianwei Liu; Alex K Price; Yi-fen Li; Christopher T Culbertson; Jun Li
Journal:  Electrophoresis       Date:  2011-08-08       Impact factor: 3.535

8.  Rare Cell Capture in Microfluidic Devices.

Authors:  Erica D Pratt; Chao Huang; Benjamin G Hawkins; Jason P Gleghorn; Brian J Kirby
Journal:  Chem Eng Sci       Date:  2011-04-01       Impact factor: 4.311

9.  Multiplexed detection of bacteria and toxins using a microflow cytometer.

Authors:  Jason S Kim; George P Anderson; Jeffrey S Erickson; Joel P Golden; Mansoor Nasir; Frances S Ligler
Journal:  Anal Chem       Date:  2009-07-01       Impact factor: 6.986

10.  Electrically addressable vesicles: tools for dielectrophoresis metrology.

Authors:  Salil P Desai; Michael D Vahey; Joel Voldman
Journal:  Langmuir       Date:  2009-04-09       Impact factor: 3.882

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.