Literature DB >> 16802488

Protein contamination of the Laryngeal Mask Airway and its relationship to re-use.

J Greenwood1, N Green, G Power.   

Abstract

The Laryngeal Mask Airway is a reusable device for maintaining the patency of a patient's airway during general anaesthesia. The device can be reused after it has been cleaned and sterilized. Protein contamination of medical instruments is a concern and has been found to occur despite standard sterilization techniques. The reason for the concern relates to the possibility of the transmission of prions and the risk of developing a neurodegenerative disorder such as Creutzveldt-Jacob disease. The purpose of this study was to quantify the amount of protein contamination that occurs, and to relate this to the number of times the Laryngeal Mask Airway has been used. Fifty previously used Classic Laryngeal Masks were collected after routine sterilization and packaging. The devices were immersed in protein detecting stain and then visual inspection performed to assess the degree and distribution of the staining. The researcher was blinded to the number of times the Laryngeal Mask Airway had been used. Linear regression analysis of the degrees of staining of the airway revealed that protein contamination occurs after the first use of the device and this increases with each subsequent use. This finding highlights the concern that the currently used cleaning and sterilization methods do not prevent the accumulation of proteinaceous material on Laryngeal Mask Airways. Consideration should be given to the search for more efficient cleaning and sterilization techniques or the use of disposable devices.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16802488     DOI: 10.1177/0310057X0603400312

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  2 in total

1.  The clinical effectiveness of the streamlined liner of pharyngeal airway (SLIPA) compared with the laryngeal mask airway ProSeal during general anesthesia.

Authors:  Yun Mi Choi; Su Man Cha; Hyun Kang; Chong Wha Baek; Yong Hun Jung; Young Cheol Woo; Jin Yun Kim; Gill Hoi Koo; Sun Gyoo Park
Journal:  Korean J Anesthesiol       Date:  2010-05-29

2.  Comparision of Ambu AuraGain™ and LMA® ProSeal in children under controlled ventilation.

Authors:  Reesha Joshi; Priya Rudingwa; Pankaj Kundra; Sakthirajan Panneerselvam; Sandeep K Mishra
Journal:  Indian J Anaesth       Date:  2018-06
  2 in total