Literature DB >> 16800373

Tricuspid valve stenosis related to subvalvular adhesion of pacemaker lead: a case report.

Kayano Taira1, Asumi Suzuki, Akihisa Fujino, Tatsuya Watanabe, Atsuhiro Ogyu, Kouichi Ashikawa.   

Abstract

Endocardial pacemaker leads may cause tricuspid valve regurgitation, but only four cases of tricuspid stenosis without endocarditis have been reported. A 77-year-old woman had received three endocardial leads when aged 44, 57, and 72 years. One lead pushed up the septal leaflet of the tricuspid valve from below the valve, then adhered to the leaflet, and was positioned against the ventricular septum. Tricuspid valve stenosis and moderate regurgitation were separately detected by transthoracic echocardiography. The tricuspid valve orifice area was 0.93 cm2 at cardiac catheterization. An excessive loop of a ventricular lead, especially a subvalvular loop, can cause opening limitation of the tricuspid valve, and the entangling of the lead in the subvalvular structures can easily induce reactive fibrosis and adhesions.

Entities:  

Mesh:

Year:  2006        PMID: 16800373

Source DB:  PubMed          Journal:  J Cardiol        ISSN: 0914-5087            Impact factor:   3.159


  6 in total

1.  Combined epicardial and transvenous placement of an implantable cardioverter defibrillator (ICD) lead without a median sternotomy in an 8-year-old child.

Authors:  Stefan Pokall; Jürgen Hörer; Christian Schreiber
Journal:  Pediatr Cardiol       Date:  2012-10-07       Impact factor: 1.655

2.  Tricuspid stenosis: An emerging disease in cardiac implantable electronic devices era. Case report and literature review.

Authors:  Aysha Husain; Faris Tufail Raja; Ahmed Fatallah; Bahaa Fadel; Aly Alsanei; Fahad Tufail Raja; Bandar AlGhamdi
Journal:  J Cardiol Cases       Date:  2017-04-14

3.  Severe tricuspid valve stenosis secondary to pacemaker leads presenting as ascites and liver dysfunction: a complex problem requiring a multidisciplinary therapeutic approach.

Authors:  Anita Krishnan; Achintya Moulick; Pranava Sinha; Karen Kuehl; Joshua Kanter; Michael Slack; Jonathan Kaltman; Marco Mercader; Jeffrey P Moak
Journal:  J Interv Card Electrophysiol       Date:  2008-10-11       Impact factor: 1.900

Review 4.  Ventricular pacing - Electromechanical consequences and valvular function.

Authors:  Elisa Ebrille; Christopher V DeSimone; Vaibhav R Vaidya; Anwar A Chahal; Vuyisile T Nkomo; Samuel J Asirvatham
Journal:  Indian Pacing Electrophysiol J       Date:  2016-03-04

5.  Severe Tricuspid Stenosis Secondary to Permanent Pacemaker Lead.

Authors:  Asif Khan; Ahmad Mustafa; Joanne Ling; James Lafferty
Journal:  J Med Cases       Date:  2022-08-19

6.  High traffic congestion in right atrium.

Authors:  S Mehrotra; Bhupesh Kumar; R Vijayvergiya; S Mathew
Journal:  Indian Heart J       Date:  2016-04-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.