Literature DB >> 16798299

In vitro comparison of aortic valve movement after valve-preserving aortic replacement.

Roland Fries1, Thomas Graeter, Diana Aicher, Helmut Reul, Christoph Schmitz, Michael Böhm, Hans-Joachim Schäfers.   

Abstract

OBJECTIVE: In aortic valve regurgitation and aortic dilatation, preservation of the aortic valve is possible by means of root remodeling (Yacoub procedure) or valve reimplantation (David procedure). In vivo studies suggest that reimplantation might substantially influence aortic valve-motion characteristics. Evaluation of aortic valve movement in vivo, however, is technically limited and is difficult to standardize. We evaluated the aortic valve-motion pattern echocardiographically in vitro after reimplantation and remodeling.
METHODS: By using aortic roots of house pigs (aortoventricular diameter, 22 mm) a Yacoub procedure (22-mm graft; group Y, n = 5) or a David I procedure (24-mm graft; group D, n = 5) was performed. Roots after supracommissural replacement (22-mm graft; group C, n = 5) served as control valves. In an electrohydraulic, computer-controlled pulse duplicator the valves were tested at flows of 2, 4, 7, and 9 L/min. Echocardiographically assessed parameters were rapid valve-opening velocity, slow valve-closing velocity, rapid valve-closing velocity, rapid valve-opening time, rapid valve-closing time, ejection time, maximum valve opening, slow valve-closing displacement, and maximum flow velocity.
RESULTS: Mean rapid valve-opening velocity and mean rapid valve-closing velocity at a cardiac output of 2 to 9 L/min were fastest in group D (rapid valve-opening velocity: 69 +/- 10 cm/s [group D] vs 39 +/- 4 cm/s [group Y] vs 42 +/- 4 cm/s [group C], P = .0041; rapid valve-closing velocity: 22 +/- 2 cm/s [group D] vs 16 +/- 2 cm/s [group Y] vs 17 +/- 1 cm/s [group C], P = .0272), and slow valve-closing velocity was slowest in group D (0.2 +/- 0.1 cm/s [group D] vs 1.0 +/- 0.3 cm/s [group Y] vs 0.6 +/- 0.1 cm/s [group C], P = .0063). With increasing cardiac output, the difference in rapid valve-opening velocity between the groups increased, the difference in slow valve-closing velocity remained unchanged, and the difference in rapid valve-closing velocity decreased.
CONCLUSIONS: In this standardized experimental setting remodeling of the aortic valve provides significantly smoother valve movements. This might contribute to preservation of a better valve performance during long-term follow-up.

Entities:  

Mesh:

Year:  2006        PMID: 16798299     DOI: 10.1016/j.jtcvs.2006.02.034

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  11 in total

1.  Valve sparing root replacement: the remodeling technique with external ring annuloplasty.

Authors:  Emmanuel Lansac; Isabelle Di Centa; Jan Vojacek; Jan Nijs; Jaroslav Hlubocky; Gianclaudio Mecozzi; Mathieu Debauchez
Journal:  Ann Cardiothorac Surg       Date:  2013-01

2.  Root remodeling for aortic root dilatation.

Authors:  Hans-Joachim Schäfers; Diana Aicher
Journal:  Ann Cardiothorac Surg       Date:  2013-01

Review 3.  Aortic valve repair update.

Authors:  Tatsuhiko Komiya
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-02-05

Review 4.  Toward standardization of valve-sparing root replacement and annuloplasty.

Authors:  Takashi Kunihara
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-09-17

Review 5.  Aortic valve repair for aortic regurgitation and preoperative echocardiographic assessment.

Authors:  Takashi Kunihara
Journal:  J Med Ultrason (2001)       Date:  2018-09-19       Impact factor: 1.314

Review 6.  Valve-sparing aortic root replacement in patients with Marfan syndrome-the Homburg experience.

Authors:  Ulrich Schneider; Tristan Ehrlich; Irem Karliova; Christian Giebels; Hans-Joachim Schäfers
Journal:  Ann Cardiothorac Surg       Date:  2017-11

Review 7.  Overview of current surgical strategies for aortic disease in patients with Marfan syndrome.

Authors:  Shunsuke Miyahara; Yutaka Okita
Journal:  Surg Today       Date:  2015-11-19       Impact factor: 2.549

8.  Aortic valve opening and closure: the clover dynamics.

Authors:  Emmanuel Lansac; Hou-Sen Lim; Yu Shomura; Khee Hiang Lim; Nolan T Rice; Isabelle Di Centa; Pouya Youssefi; Wolfgang Goetz; Carlos M G Duran
Journal:  Ann Cardiothorac Surg       Date:  2019-05

9.  Visualization of Human Aortic Valve Dynamics Using Magnetic Resonance Imaging with Sub-Millisecond Temporal Resolution.

Authors:  Zheng Zhong; Kaibao Sun; Guangyu Dan; Qingfei Luo; Afshin Farzaneh-Far; Meryem Muge Karaman; Xiaohong Joe Zhou
Journal:  J Magn Reson Imaging       Date:  2021-03-24       Impact factor: 5.119

Review 10.  Old Myths, New Concerns: the Long-Term Effects of Ascending Aorta Replacement with Dacron Grafts. Not All That Glitters Is Gold.

Authors:  Cristiano Spadaccio; Francesco Nappi; Nawwar Al-Attar; Fraser W Sutherland; Christophe Acar; Antonio Nenna; Marcella Trombetta; Massimo Chello; Alberto Rainer
Journal:  J Cardiovasc Transl Res       Date:  2016-05-31       Impact factor: 4.132

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.