Literature DB >> 16798184

Intraaortic balloon pumping during cardioplegic arrest preserves lung function in patients with chronic obstructive pulmonary disease.

Francesco Onorati1, Lucia Cristodoro, Massimo Bilotta, Barbara Impiombato, Francesco Pezzo, Pasquale Mastroroberto, Antonio di Virgilio, Attilio Renzulli.   

Abstract

BACKGROUND: Linear flow during cardiopulmonary bypass is considered a potential mechanism of lung damage in patients with chronic obstructive pulmonary disease (COPD). We evaluated differences in lung function of patients with COPD undergoing preoperative intraaortic balloon pumping (IABP), between linear flow during cardiopulmonary bypass (IABP-off) and maintenance of pulsatile flow (IABP-on at automatic 80 bpm) during cardioplegic arrest.
METHODS: Fifty patients with COPD undergoing preoperative IABP were randomized between January 2004 and July 2005 to receive nonpulsatile cardiopulmonary bypass with IABP discontinued during cardioplegic arrest (25 patients; group A), or IABP-induced pulsatile cardiopulmonary bypass (25 patients; group B). Hospital outcome, need for noninvasive ventilation, oxygenation (partial pressure of oxygen, arterial to fraction of inspired oxygen [Pao(2)/Fio(2])), respiratory system compliance, and scoring of chest radiographs were compared.
RESULTS: There were no hospital deaths, no IABP-related complications, and no differences in postoperative noninvasive ventilation (group A: 6 of 25, 24.0% vs group B: 5 of 25, 20%; p = not significant [NS]). One patient in both groups developed pneumonia (p = NS). Intensive care and hospital stay were comparable (p = NS). Group B showed lower intubation time (8.3 +/- 5.1 hours versus group A: 13.2 +/- 6.0; p = 0.001), better Pao(2)/Fio(2) at aortic declamping (369.5 +/- 93.7 mm Hg vs 225.7 +/- 99.3; p = 0.001) at admission in intensive care (321.3 +/- 96.9 vs 246.2 +/- 109.7; p = 0.003), and at 24 hours (349.8 +/- 100.4 vs 240.8 +/- 77.3; p = 0.003). The respiratory system compliance was better in group B at the end of surgery (56.4 +/- 8.2 mL/cm H(2)O vs 49.4 +/- 7.0; p = 0.004) and 8 hours postoperatively (76.4 +/- 8.2 vs 59.4 +/- 7.0; p = 0.0001), as well as scoring of chest radiograph at intensive care admission (0.20 +/- 0.41 vs 0.38 +/- 0.56; p = 0.05) and on the first day (0.26 +/- 0.45 vs 0.50 +/- 0.67; p = 0.025).
CONCLUSIONS: Automatic 80 bpm IABP during cardioplegic arrest preserves lung function in patients with COPD.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16798184     DOI: 10.1016/j.athoracsur.2006.02.045

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Effects of pulsatile perfusion during cardiopulmonary bypass on biochemical markers and kidney function in patients undergoing cardiac surgeries.

Authors:  Alireza Mohammadzadeh; Naser Jafari; Mohammad Hasanpour; Soheil Sahandifar; Masoud Ghafari; Vahed Alaei
Journal:  Am J Cardiovasc Dis       Date:  2013-08-16

2.  Outcomes of Venoarterial Extracorporeal Membrane Oxygenation Plus Intra-Aortic Balloon Pumping for Treatment of Acute Myocardial Infarction Complicated by Cardiogenic Shock.

Authors:  Takeshi Nishi; Masanobu Ishii; Kenichi Tsujita; Hiroshi Okamoto; Satoshi Koto; Michikazu Nakai; Yoko Sumita; Yoshitaka Iwanaga; Satoaki Matoba; Yoshio Kobayashi; Ken-Ichi Hirata; Yutaka Hikichi; Hiroyoshi Yokoi; Yuji Ikari; Shiro Uemura
Journal:  J Am Heart Assoc       Date:  2022-04-04       Impact factor: 6.106

3.  Degree of risk related to procedures performed in conjunction with surgical myocardial revascularization in octogenarians.

Authors:  Jose Carlos Rossini Iglezias; Luis Alberto Oliveira Dallan; Artur Lourenção; Alex Luiz Celullare; Raiane Pereira; Noedir Antonio Groppo Stolf
Journal:  Clinics (Sao Paulo)       Date:  2009-05       Impact factor: 2.365

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.