BACKGROUND: The aim of the study is to prospectively determine the incidence of inflow stenoses in dysfunctional hemodialysis access arteriovenous fistulae (AVFs) and grafts (AVGs).
METHODS: Contrast-enhanced magnetic resonance angiography (CE-MRA) was performed of 66 dysfunctional AVFs and 35 AVGs in 56 men and 45 women (mean age, 62 years; age range, 31 to 86 years). Complete inflow (from the subclavian artery), shunt region, and complete outflow (including subclavian vein) were shown at CE-MRA. In addition to standard digital subtraction angiography (DSA) of the shunt region and outflow, DSA of the complete inflow was obtained through access catheterization of all cases in which CE-MRA showed an inflow stenosis. Vascular stenosis is defined as greater than 50% decrease in luminal diameter compared with an uninvolved vascular segment located adjacent to the stenosis. Endovascular intervention of stenoses was performed in connection with DSA.
RESULTS: CE-MRA showed 19 arterial stenoses in 14 patients (14%). DSA confirmed 18 of these lesions in 13 patients and showed no additional inflow lesions. Of the 13 patients, 7 patients had arterial stenoses only and 6 patients had accompanying stenoses in the shunt region and/or outflow. Referral criteria for the 13 patients to undergo access evaluation had been decreased flow rates (9 patients), steal symptoms (2 patients), and insufficient access maturation (2 patients). Access flow of the 9 patients with a low-flow access improved from 477 +/- 74 mL/min to 825 +/- 199 mL/min after angioplasty. One patient with steal symptoms became symptom free after angioplasty. Endovascular intervention in 3 patients proved to be unsuccessful.
CONCLUSION: Inflow stenoses are not uncommon in dysfunctional hemodialysis access shunts. We suggest that radiological evaluation comprise assessment of the complete arterial inflow.

Entities:  

Mesh:

Year:  2006        PMID: 16797391     DOI: 10.1053/j.ajkd.2006.03.076

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  10 in total

1.  Reliability of ultrasound duplex for detection of hemodynamically significant stenosis in hemodialysis access.

Authors:  Ashvin Vardza Raju; Kyin Kyin May; Min Htet Zaw; Carolina Capistrano Canlas; Mary Hannah Seah; Catherine Menil Serrano; Mikael Hartman; Pei Ho
Journal:  Ann Vasc Dis       Date:  2013-02-15

2.  Surveillance of hemodialysis vascular access.

Authors:  William L Whittier
Journal:  Semin Intervent Radiol       Date:  2009-06       Impact factor: 1.513

3.  Expanding use of embolic protection devices.

Authors:  Martin G Radvany; Michael Wholey
Journal:  Semin Intervent Radiol       Date:  2008-03       Impact factor: 1.513

4. 

Authors:  Rohan Arasu; Dev Jegatheesan; Yogeesan Sivakumaran
Journal:  Can Fam Physician       Date:  2022-08       Impact factor: 3.025

Review 5.  Overview of hemodialysis access and assessment.

Authors:  Rohan Arasu; Dev Jegatheesan; Yogeesan Sivakumaran
Journal:  Can Fam Physician       Date:  2022-08       Impact factor: 3.025

Review 6.  Definitions and End Points for Interventional Studies for Arteriovenous Dialysis Access.

Authors:  Gerald A Beathard; Charmaine E Lok; Marc H Glickman; Ahmed A Al-Jaishi; Donna Bednarski; David L Cull; Jeffery H Lawson; Timmy C Lee; Vandana D Niyyar; Donna Syracuse; Scott O Trerotola; Prabir Roy-Chaudhury; Surendra Shenoy; Margo Underwood; Haimanot Wasse; Karen Woo; Theodore H Yuo; Thomas S Huber
Journal:  Clin J Am Soc Nephrol       Date:  2017-07-20       Impact factor: 8.237

7.  Retarded hand growth due to a hemodialysis fistula in a young girl.

Authors:  Frank van Hoek; Marc R Scheltinga; Attila G Krasznai; E A Marlies Cornelissen
Journal:  Pediatr Nephrol       Date:  2009-05-15       Impact factor: 3.714

Review 8.  Optimal hemodialysis vascular access in the elderly patient.

Authors:  Louise M Moist; Charmaine E Lok; Tushar J Vachharajani; Wang Xi; Ahmed AlJaishi; Kevan R Polkinghorne; Miguel Vazquez; Timmy C Lee
Journal:  Semin Dial       Date:  2012 Nov-Dec       Impact factor: 3.455

9.  Surveillance and monitoring of dialysis access.

Authors:  Lalathaksha Kumbar; Jariatul Karim; Anatole Besarab
Journal:  Int J Nephrol       Date:  2011-11-22

10.  Diagnostic accuracy of computer tomography angiography and magnetic resonance angiography in the stenosis detection of autologuous hemodialysis access: a meta-analysis.

Authors:  Bin Li; Qiong Li; Cong Chen; Yu Guan; Shiyuan Liu
Journal:  PLoS One       Date:  2013-10-23       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.