Sounding airflow enhances aerosol delivery into the paranasal sinuses.

M Maniscalco1, M Sofia, E Weitzberg, J O Lundberg.   

Abstract

BACKGROUND: The use of aerosol therapy is commonly suggested in the treatment of paranasal disorders but it is difficult to achieve an effective penetration of drugs into the sinuses. The authors have recently shown that an oscillating airflow produced by phonation (nasal humming) causes a large increase in the gas exchange between the nose and the paranasal sinuses. This is reflected by a high peak in nasally exhaled nitric oxide (NO) levels because NO accumulated in the sinuses is rapidly washed-out via the sinus ostia.
OBJECTIVE: This study was designed to test whether the increase in sinus gas exchange caused by an oscillating airflow could be used to enhance penetration of a drug into the sinuses.
MATERIALS AND METHODS: In six healthy subjects a nitric oxide-synthase inhibitor L-NAME was administrated into the nostrils by a jet nebulizer connected to a duck call, which could be modified to generate either a sounding airflow or a non-sounding airflow. The degree of L-NAME penetration into the sinuses was judged from the reduction in nasal NO during humming exhalations. Sinus drug deposition was also studied in a model of the nose and sinus.
RESULTS: In humans the delivery of L-NAME with the non-sounding airflow had no effect on the NO levels achieved during humming, whereas L-NAME administration with sound caused a significant 22-35% reduction in nasal NO. In the model the aerosol delivery with the sounding airflow caused a fourfold increase in sinus drug deposition as compared with an aerosol without sound.
CONCLUSION: A sounding airflow increases the delivery of an aerosolized drug into the paranasal sinuses.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16796609     DOI: 10.1111/j.1365-2362.2006.01654.x

Source DB:  PubMed          Journal:  Eur J Clin Invest        ISSN: 0014-2972            Impact factor:   4.686


  5 in total

1.  Impact of airborne particle size, acoustic airflow and breathing pattern on delivery of nebulized antibiotic into the maxillary sinuses using a realistic human nasal replica.

Authors:  Lara Leclerc; Jérémie Pourchez; Gérald Aubert; Sandrine Leguellec; Laurent Vecellio; Michèle Cottier; Marc Durand
Journal:  Pharm Res       Date:  2014-03-04       Impact factor: 4.200

Review 2.  Inhalable Antimicrobials for Treatment of Bacterial Biofilm-Associated Sinusitis in Cystic Fibrosis Patients: Challenges and Drug Delivery Approaches.

Authors:  Sylvia Natalie Kłodzińska; Petra Alexandra Priemel; Thomas Rades; Hanne Mørck Nielsen
Journal:  Int J Mol Sci       Date:  2016-10-09       Impact factor: 5.923

3.  Xenon-Enhanced Dynamic Dual-Energy CT Is Able to Quantify Sinus Ventilation Using Laminar and Pulsating Air-/Gas Flow Before and After Surgery: A Pilot Study in a Cadaver Model.

Authors:  Sven Becker; Tilman Huppertz; Winfried Möller; Miriam Havel; Maria Schuster; Anne Merle Becker; Martin Sailer; Uwe Schuschnig; Thorsten R Johnson
Journal:  Front Allergy       Date:  2022-02-16

4.  Topical drug delivery in chronic rhinosinusitis patients before and after sinus surgery using pulsating aerosols.

Authors:  Winfried Möller; Uwe Schuschnig; Gülnaz Celik; Wolfgang Münzing; Peter Bartenstein; Karl Häussinger; Wolfgang G Kreyling; Martin Knoch; Martin Canis; Sven Becker
Journal:  PLoS One       Date:  2013-09-11       Impact factor: 3.240

5.  Numerical optimization of targeted delivery of charged nanoparticles to the ostiomeatal complex for treatment of rhinosinusitis.

Authors:  Jinxiang Xi; Jiayao Eddie Yuan; Xiuhua April Si; James Hasbany
Journal:  Int J Nanomedicine       Date:  2015-07-30