Literature DB >> 16793781

Length of insertion for pulmonary artery catheters to locate different cardiac chambers in patients undergoing cardiac surgery.

D K Tempe1, A Gandhi, V Datt, M Gupta, A S Tomar, V Rajesh, S Virmani, A Banerjee.   

Abstract

BACKGROUND: Although, guidelines related to length of insertion of a pulmonary artery catheter to reach a particular cardiac chamber are available, these are not backed by clinical studies. We measured the length of insertion of pulmonary artery catheters to locate the right ventricle, pulmonary artery and pulmonary capillary wedge positions in 300 adult patients undergoing elective cardiac surgery.
METHODS: The pulmonary artery catheters were inserted using a standard technique through the right internal jugular vein. The right ventricle, pulmonary artery and wedge position of the catheter were confirmed by the characteristic waveforms, and the length of insertion to these points was measured.
RESULTS: The right ventricle was reached at 24.6 (3) cm (95% CI 24.2-24.9 cm), pulmonary artery at 36 (4) cm (95% CI 35.6-36.5 cm) and wedge position at 42.8 (5.7) cm (95% CI 42.2-43.5 cm). The length of catheter to reach the right ventricle, pulmonary artery and wedge position was significantly more in patients undergoing valve surgery as compared with those undergoing coronary artery bypass grafting [26 (3.8) and 24 (2.5) cm; 38.5 (4.6) and 35 (3.2) cm; and 47.8 (6.9) and 41.2 (4.1) cm, respectively, P<0.001]. The length of insertion to reach pulmonary artery and pulmonary capillary wedge position was directly related to height of the patient (Pearson's correlation 0.157 and 0.15, respectively).
CONCLUSIONS: We have provided the norms related to length of insertion of pulmonary artery catheter, which should be useful in accurate placement of the catheter and minimize complications related to coiling of the catheter.

Entities:  

Mesh:

Year:  2006        PMID: 16793781     DOI: 10.1093/bja/ael150

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  6 in total

1.  Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report.

Authors:  Daisuke Sugiyama; Shigeo Ikeno; Tetsuya Tsuchihashi; Shigeru Yokota; Hiroaki Ina; Tetsuya Kono; Kunihiko Yamashita; Mikito Kawamata
Journal:  Korean J Anesthesiol       Date:  2014-11-26

2.  Identical wave forms of vena cava and pulmonary artery during pulmonary artery catheter insertion due to kinking: a case report of a rare complication.

Authors:  Masayuki Oshima; Tatsuki Onishi; Hitomi Iwata; Kazuyoshi Aoyama
Journal:  Springerplus       Date:  2016-08-19

3.  An analysis of the factors producing multiple ventricular arrhythmias during pulmonary artery catheterization.

Authors:  Hajime Satoh; Yuka Miyata; Tomohiko Hayasaka; Tsutomu Wada; Yukio Hayashi
Journal:  Ann Card Anaesth       Date:  2017 Apr-Jun

4.  An analysis of prior experience influencing quality of pulmonary artery catheter placement in residents.

Authors:  Hirofumi Hamaba; Yuka Miyata; Tsutomu Wada; Tomohiko Hayasaka; Yukio Hayashi
Journal:  Ann Card Anaesth       Date:  2020 Apr-Jun

5.  Where does the pulmonary artery catheter float: transesophageal echocardiography evaluation.

Authors:  Deepak K Tempe; Upma Bhatia Batra; Vishnu Datt; Akhlesh Singh Tomar; Sanjula Virmani
Journal:  Ann Card Anaesth       Date:  2015 Oct-Dec

Review 6.  The contemporary pulmonary artery catheter. Part 1: placement and waveform analysis.

Authors:  I T Bootsma; E C Boerma; F de Lange; T W L Scheeren
Journal:  J Clin Monit Comput       Date:  2021-02-10       Impact factor: 2.502

  6 in total