Literature DB >> 16792609

Determination of the site of tracheal tube impingement during nasotracheal fibreoptic intubation.

A G Marfin1, R Iqbal, F Mihm, M T Popat, S H Scott, J J Pandit.   

Abstract

This study examines the incidence and site of tracheal tube impingement during nasotracheal fibreoptic intubation, and the efficacy of anticlockwise tube rotation to overcome the problem. Forty-three patients underwent fibreoptic-assisted nasotracheal intubation using a preformed nasal tube, and a second fibrescope was used to observe any obstruction to passage of the tracheal tube. Impingement occurred in 10 cases, with the most common site being the right arytenoid cartilage. Rotation resulted in successful intubation in all 10 cases, but proximal rotation did not always result in an equal degree of rotation at the tube tip. We conclude that the site of impingement for nasotracheal intubation with preformed nasal tubes is located at the posterior structures of the laryngeal inlet and that anticlockwise rotation is a simple and effective solution.

Entities:  

Mesh:

Year:  2006        PMID: 16792609     DOI: 10.1111/j.1365-2044.2006.04652.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  12 in total

Review 1.  [Awake fiberoptic intubation].

Authors:  F Gerheuser; K Gürtler
Journal:  Anaesthesist       Date:  2011-12       Impact factor: 1.041

2.  Comparison of two different methods of fiber-optic nasal intubation: conventional method versus facilitated method (NASAL-18).

Authors:  Ali Mohammadzadeh; Mohammad Haghighi; Bahram Naderi; Amanullah Chaudhry; Zahid Hussain Khan; Mohammad R Rasouli; Soheil Saadat
Journal:  Ups J Med Sci       Date:  2011-02-15       Impact factor: 2.384

3.  Nasotracheal intubation of a patient with restricted mouth opening using a McGrath MAC X-Blade and Magill forceps.

Authors:  Zehra İpek Arslan; P Ozdal; D Ozdamar; H Agır; M Solak
Journal:  J Anesth       Date:  2016-06-24       Impact factor: 2.078

4.  Patient factors associated with difficult flexible bronchoscopic intubation under general anesthesia: a prospective observational study.

Authors:  Taher Touré; Stephan R Williams; Mahmoud Kerouch; Monique Ruel
Journal:  Can J Anaesth       Date:  2020-01-17       Impact factor: 5.063

5.  Time to tracheal intubation over a fibreoptic bronchoscope using a silicone left double-lumen endobronchial tube versus polyvinyl chloride single-lumen tube with bronchial blocker: a randomized controlled non-inferiority trial.

Authors:  Ji Young Yoo; Yun Jeong Chae; Sung Yong Park; Seokjin Haam; Myungseob Kim; Dae Hee Kim
Journal:  J Thorac Dis       Date:  2019-03       Impact factor: 2.895

6.  All India Difficult Airway Association 2016 guidelines for the management of unanticipated difficult tracheal intubation in adults.

Authors:  Sheila Nainan Myatra; Amit Shah; Pankaj Kundra; Apeksh Patwa; Venkateswaran Ramkumar; Jigeeshu Vasishtha Divatia; Ubaradka S Raveendra; Sumalatha Radhakrishna Shetty; Syed Moied Ahmed; Jeson Rajan Doctor; Dilip K Pawar; Singaravelu Ramesh; Sabyasachi Das; Rakesh Garg
Journal:  Indian J Anaesth       Date:  2016-12

Review 7.  Nasal intubation: A comprehensive review.

Authors:  Varun Chauhan; Gaurav Acharya
Journal:  Indian J Crit Care Med       Date:  2016-11

8.  A comparison of the Macintosh laryngoscope, McGrath video laryngoscope, and Pentax Airway Scope in paediatric nasotracheal intubation.

Authors:  Ji Young Yoo; Yun Jeong Chae; Young Bok Lee; Sujin Kim; Jaemoon Lee; Dae Hee Kim
Journal:  Sci Rep       Date:  2018-11-26       Impact factor: 4.379

9.  Effects of head positions on awake fiberoptic bronchoscope oral intubation: a randomized controlled trial.

Authors:  Zhuo Liu; Li Zhao; Zhongfeng Ma; Meiqi Liu; Xiaohang Qi; Qianqian Jia; Shujuan Liang; Xiaochun Yang
Journal:  BMC Anesthesiol       Date:  2021-06-23       Impact factor: 2.217

10.  Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults.

Authors:  C Frerk; V S Mitchell; A F McNarry; C Mendonca; R Bhagrath; A Patel; E P O'Sullivan; N M Woodall; I Ahmad
Journal:  Br J Anaesth       Date:  2015-11-10       Impact factor: 9.166

View more