Time dependence of 3He diffusion in the human lung: measurement in the long-time regime using stimulated echoes.

Chengbo Wang1, G Wilson Miller, Talissa A Altes, Eduard E de Lange, Gordon D Cates, John P Mugler.   

Abstract

A stimulated-echo-based technique was developed to measure the long-time-scale apparent diffusion coefficient (ADC) of hyperpolarized 3He during a single breath-hold acquisition. Computer simulations were used to evaluate the performance of the technique and guide the selection of appropriate parameter values for obtaining accurate ADC values. The technique was used in 10 healthy subjects and two subjects with chronic obstructive pulmonary disease (COPD) to measure the global ADC for diffusion times between a few tenths of a second and several seconds, and to acquire spatial maps of the ADC for a diffusion time of 1.5 s. The reproducibility of the technique and its sensitivity to the direction of diffusion sensitization were also investigated. In healthy subjects, global ADC values decreased by severalfold over the range of diffusion times measured (mean values = 0.039 and 0.023 cm2/s at diffusion times of 0.61 and 1.54 s, respectively). ADC maps were generally uniform, with mean values similar to the corresponding global values. For the two COPD subjects, global ADC values were substantially greater than those of every healthy subject at all diffusion times measured. In addition, regional elevations of ADC values were far more conspicuous on long-time-scale ADC maps than on short-time-scale ADC maps. Copyright 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16791861     DOI: 10.1002/mrm.20944

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

1.  How accurately can the parameters from a model of anisotropic 3He gas diffusion in lung acinar airways be estimated? Bayesian view.

Authors:  Alexander L Sukstanskii; G Larry Bretthorst; Yulin V Chang; Mark S Conradi; Dmitriy A Yablonskiy
Journal:  J Magn Reson       Date:  2006-10-09       Impact factor: 2.229

2.  In vivo lung morphometry with hyperpolarized 3He diffusion MRI: theoretical background.

Authors:  A L Sukstanskii; D A Yablonskiy
Journal:  J Magn Reson       Date:  2007-11-01       Impact factor: 2.229

3.  Role of collateral paths in long-range diffusion in lungs.

Authors:  Seth-Emil T Bartel; Susan E Haywood; Jason C Woods; Yulin V Chang; Christopher Menard; Dmitriy A Yablonskiy; David S Gierada; Mark S Conradi
Journal:  J Appl Physiol (1985)       Date:  2008-02-21

Review 4.  Functional imaging: CT and MRI.

Authors:  Edwin J R van Beek; Eric A Hoffman
Journal:  Clin Chest Med       Date:  2008-03       Impact factor: 2.878

Review 5.  3He diffusion MRI in human lungs.

Authors:  Jason C Woods; Mark S Conradi
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

6.  Helium-3 diffusion MR imaging of the human lung over multiple time scales.

Authors:  John P Mugler; Chengbo Wang; G Wilson Miller; Gordon D Cates; Jaime F Mata; James R Brookeman; Eduard E de Lange; Talissa A Altes
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

7.  Lung injury induced by secondhand smoke exposure detected with hyperpolarized helium-3 diffusion MR.

Authors:  Chengbo Wang; John P Mugler; Eduard E de Lange; James T Patrie; Jaime F Mata; Talissa A Altes
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

8.  Novel Thoracic MRI Approaches for the Assessment of Pulmonary Physiology and Inflammation.

Authors:  Jonathan P Brooke; Ian P Hall
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

9.  Simultaneous measurement of pulmonary partial pressure of oxygen and apparent diffusion coefficient by hyperpolarized 3He MRI.

Authors:  Jiangsheng Yu; Michelle Law; Stephen Kadlecek; Kiarash Emami; Masaru Ishii; Michael Stephen; John M Woodburn; Vahid Vahdat; Rahim R Rizi
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

10.  Assessment of the lung microstructure in patients with asthma using hyperpolarized 3He diffusion MRI at two time scales: comparison with healthy subjects and patients with COPD.

Authors:  Chengbo Wang; Talissa A Altes; John P Mugler; G Wilson Miller; Kai Ruppert; Jaime F Mata; Gordon D Cates; Larry Borish; Eduard E de Lange
Journal:  J Magn Reson Imaging       Date:  2008-07       Impact factor: 4.813

View more