Literature DB >> 16791066

Biomechanical analysis of in situ single versus double screw fixation in a nonreduced slipped capital femoral epiphysis model.

Lee S Segal1, Justin A Jacobson, Marnie M Saunders.   

Abstract

Slipped capital femoral epiphyses (SCFE) were created in 24 pairs of immature bovine femurs. In 17 pairs of femurs, the slip was left nonreduced (one-third diameter of physis), and in 7 pairs, the slip was reduced. Stabilization of the slips was with either 1 or 2 threaded 6.5-mm screws in a compression mode. The specimens were subjected to shear or torsional loading forces to failure, with the goal of trying to reproduce clinical conditions of in situ screw fixation for acute or unstable SCFE. In the nonreduced model, double-screw fixation was 312% stiffer than single-screw fixation under torsional loading. In the reduced model, double-screw fixation was 137% stiffer than single-screw fixation under torsional loading. The increased rotational stability of double-screw fixation under torsional loading conditions may justify its use in in situ stabilization of acute or unstable SCFE.

Entities:  

Mesh:

Year:  2006        PMID: 16791066     DOI: 10.1097/01.bpo.0000226285.46943.ea

Source DB:  PubMed          Journal:  J Pediatr Orthop        ISSN: 0271-6798            Impact factor:   2.324


  5 in total

1.  In situ fixation of slipped capital femoral epiphysis with Steinmann pins.

Authors:  Trude G Lehmann; Ingvild Ø Engesæter; Lene B Laborie; Karen Rosendahl; Stein Atle Lie; Lars B Engesæter
Journal:  Acta Orthop       Date:  2011-04-20       Impact factor: 3.717

2.  Lateral insertion is a good prognostic factor after in situ fixation in slipped capital femoral epiphysis.

Authors:  Shigeo Hagiwara; Junichi Nakamura; Makoto Kamegaya; Takashi Saisu; Jun Kakizaki; Seiji Ohtori; Shunji Kishida; Kazuhisa Takahashi
Journal:  BMC Musculoskelet Disord       Date:  2014-09-26       Impact factor: 2.362

3.  Bilateral Slipped Capital Femoral Epiphysis Fixation Failure Including the Prophylactic Side: A Case Report.

Authors:  Canon C Cornelius; Surya Mundluru
Journal:  Cureus       Date:  2022-03-18

4.  Fluoroscopic imaging overestimates the screw tip to subchondral bone distance in a cadaveric model of slipped capital femoral epiphysis.

Authors:  M J Heffernan; B Snyder; H Zhou; X Li
Journal:  J Child Orthop       Date:  2017       Impact factor: 1.548

5.  A Novel Classification System for Slipped Capital Femoral Epiphysis Based on the Radiographic Relationship of the Epiphyseal Tubercle and the Metaphyseal Socket.

Authors:  Daniel A Maranho; Sarah Bixby; Patricia E Miller; Eduardo N Novais
Journal:  JB JS Open Access       Date:  2019-11-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.