Literature DB >> 16790578

Disposable infusion pumps.

Elena A Skryabina1, Teresa S Dunn.   

Abstract

PURPOSE: The properties, performance, and applications of nonelectric disposable infusion pumps are reviewed.
SUMMARY: All nonelectric disposable infusion pumps exploit the same physical principle: mechanical restriction within the flow path determines the speed of pressurized fluid. The pressure generated by disposable pumps on fluid is 250-600 mm Hg, compared with 5-1200 mm Hg of pressure for electric pumps. There are several types of disposable infusion pumps, including elastomeric, positive-pressure (spring-powered and gas-pressure-powered), negative-pressure (vacuum), and patient-controlled analgesia (PCA) pumps. The accuracy of each pump's flow rate is dependent on several factors, including temperature, fluid viscosity, atmospheric pressure, back pressure, partial filling, and storage. Disposable infusion pumps can be used in many areas, including home care, PCA, patient-controlled epidural analgesia, continuous peripheral analgesia, continuous epidural analgesia, continuous i.v. analgesia, and pediatrics applications. The advantages of disposable infusion pumps include their light weight, small size, simplicity of use, independence from an external power supply, elimination of programming errors, and disposability. Disadvantages include the possibility of inaccurate flow rates, fixed reservoir volume, lack of a facility to change the flow rate and bolus-dose volume to provide adequate analgesia, inability to trace the history of the analgesia demand by patients, inability to combine PCA with background continuous infusions, and long-term cost.
CONCLUSION: Despite some disadvantages and limited areas of applicability, disposable infusion pumps provide patients with advantages, such as portability, simplicity, and disposability, especially for the administration of analgesia. Understanding their physical and mechanical characteristics and their appropriate application may optimize patient care.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16790578     DOI: 10.2146/ajhp050408

Source DB:  PubMed          Journal:  Am J Health Syst Pharm        ISSN: 1079-2082            Impact factor:   2.637


  22 in total

1.  Administration of substances to laboratory animals: routes of administration and factors to consider.

Authors:  Patricia V Turner; Thea Brabb; Cynthia Pekow; Mary Ann Vasbinder
Journal:  J Am Assoc Lab Anim Sci       Date:  2011-09       Impact factor: 1.232

2.  Safety and effectiveness of home intravenous antibiotic therapy for multidrug-resistant bacterial infections.

Authors:  A Mujal; J Sola; M Hernandez; M-A Villarino; M-L Machado; M Baylina; J Tajan; J Oristrell
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-02-06       Impact factor: 3.267

3.  Stability of commonly used antibiotic solutions in an elastomeric infusion device.

Authors:  Scott E Walker; John Iazzetta; Shirley Law; Kristof Biniecki
Journal:  Can J Hosp Pharm       Date:  2010-05

4.  [Cost minimization analysis in postoperative pain management : economic efficiency and effectiveness of two infusion pump systems].

Authors:  A-K Bräscher; J Blunk; S Söhle; R E Feldmann; M Bauer; J Benrath
Journal:  Anaesthesist       Date:  2014-10       Impact factor: 1.041

5.  Acute profound abciximab induced thrombocytopenia: a correct management of a methodological error.

Authors:  Gaetano Tanzilli; Martina Sordi; Alessio Arrivi; Enrico Mangieri; Massimiliano Scappaticci
Journal:  BMJ Case Rep       Date:  2009-10-05

6.  Case files of the University of Massachusetts fellowship in medical toxicology: lethal dose of opioids contained in an elastomeric capsule labeled as vancomycin.

Authors:  James Courtney; Edward Boyer
Journal:  J Med Toxicol       Date:  2008-09

7.  Digital droplet infusion.

Authors:  Zecong Fang; Andrew I Li; Hong Liu; Tingrui Pan
Journal:  Lab Chip       Date:  2020-11-13       Impact factor: 6.799

Review 8.  Ambulatory chemotherapy: Past, present, and future.

Authors:  Racha Sabbagh Dit Hawasli; Stephen Barton; Shereen Nabhani-Gebara
Journal:  J Oncol Pharm Pract       Date:  2021-01-18       Impact factor: 1.809

9.  The role of continuous peripheral nerve blocks.

Authors:  José Aguirre; Alicia Del Moral; Irina Cobo; Alain Borgeat; Stephan Blumenthal
Journal:  Anesthesiol Res Pract       Date:  2012-06-18

10.  User-Centered Design: Developing the RELI Delivery System - a Low-Cost, Non-Electric, Pneumatic Infusion Pump.

Authors:  Elizabeth Abu-Haydar; David Katuntu; James Bauer; Alec Wollen; Mike Eisenstein; Jill Sherman-Konkle; Anthony Roche; Michael Ruffo
Journal:  Med Devices (Auckl)       Date:  2021-06-24
View more