Literature DB >> 1678941

Adaptive feedback-controlled infusion versus repetitive injections of vecuronium in patients during isoflurane anesthesia.

B J Ebeling1, W Müller, P Tonner, K T Olkkola, H Stoeckel.   

Abstract

STUDY
OBJECTIVE: To compare vecuronium requirements using repetitive injections and a model-based, closed-loop, feedback-controlled infusion during isoflurane anesthesia.
DESIGN: Randomized open study.
SETTING: Departments of Anesthesiology and Ear, Nose, and Throat Surgery at a university hospital. PATIENTS: Twenty-two patients of ASA physical status I or II undergoing elective otolaryngological surgery requiring general anesthesia.
INTERVENTIONS: Vecuronium was used for muscle relaxation. The desired level of neuromuscular transmission was set to 10% of control. All patients received vecuronium 0.08 mg/kg for intubation. Thereafter, vecuronium was injected repetitively in 11 patients (Group 1) whenever spontaneous recovery had reached the 10% level. In the other group of 11 patients (Group 2), relaxation was maintained by an adaptive closed-loop feedback system, which was based on a pharmacokinetic-dynamic model.
MEASUREMENTS AND MAIN RESULTS: Neuromuscular transmission was quantified by the evoked electromyogram of the hypothenar muscles. In Group 1, the first repetition of 0.02 mg/kg had to be administered after 27.0 +/- 5.5 minutes, followed by repetitions of the same dose every 16.3 +/- 3.0 minutes. The induced neuromuscular block ranged from 83% to 100%. The mean vecuronium demand was 0.123 +/- 0.018 mg/kg/h. In Group 2, stable relaxation of 90% +/- 2% was achieved within 19.2 +/- 7.5 minutes after a period of damped oscillations. The mean offset from the target value of 90% blockade was 0.65% +/- 0.32%. The average vecuronium requirement was 0.056 +/- 0.021 mg/kg/h during steady state. The difference between the groups in muscle relaxant demand was statistically significant.
CONCLUSIONS: The model-based adaptive feedback system proved to be useful in maintaining a stable degree of paralysis, adjusting relaxant input to individual demand, and minimizing drug requirement, as compared with repetitive injections.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1678941     DOI: 10.1016/0952-8180(91)90156-h

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  2 in total

1.  Influence of real-time Bayesian forecasting of pharmacokinetic parameters on the precision of a rocuronium target-controlled infusion.

Authors:  Cyrus Motamed; Jean-Michel Devys; Bertrand Debaene; Valérie Billard
Journal:  Eur J Clin Pharmacol       Date:  2012-02-19       Impact factor: 2.953

Review 2.  Beyond Genetics-Stratified and Personalised Medicines Using Multiple Parameters.

Authors:  Richard Peck; Patrick Smith
Journal:  Pharmaceuticals (Basel)       Date:  2010-05-25
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.