| Literature DB >> 16789018 |
V Enouf1, G Dos Reis, J P Guthmann, P J Guerin, M Caron, V Marechal, E Nicand.
Abstract
Since the characterization of the genome of the hepatitis E virus (HEV) in 1990, a large genetic diversity has been described. A single real-time reverse transcription (RT)-PCR assay with TaqMan technology has been validated which uses only one set of primers and probe within the ORF2 HEV region (nt 5207-5292) for the detection and quantification of the four major genotypes of HEV. This assay proved to be as efficient as the conventional RT-PCR methodology for the detection of HEV in clinical samples testing positive previously. The real-time RT-PCR and conventional RT-PCR were performed comparatively on 60 pairs of sera and stools collected during a recent outbreak of hepatitis E in Darfur. The real-time RT-PCR assay was 10- to 100-fold sensitive than for conventional RT-PCR assays used in this study with a range quantitation from 1.8 x 10(1) to 7.2 x 10(3) RNA copies/microl in clinical samples (serum and stools). 2006 Wiley-Liss, Inc.Entities:
Mesh:
Substances:
Year: 2006 PMID: 16789018 DOI: 10.1002/jmv.20665
Source DB: PubMed Journal: J Med Virol ISSN: 0146-6615 Impact factor: 2.327