Comparison of body composition measurements obtained by two fan-beam DXA instruments.

Yumiko Sakai1, Hiroyuki Ito, Toshiko Meno, Makoto Numata, Sumie Jingu.   

Abstract

Although dual-energy X-ray absorptiometry (DXA) has been widely used for measuring body composition, discrepancies have been reported to exist among results obtained from different instruments. In the course of longitudinal studies lasting for many years, old instruments may be required to be replaced with new ones, necessitating comparison and validation between the values obtained by the old and new instruments. We compared the data obtained by the two fan-beam DXA instruments, QDR-2000 (Hologic, Waltham, MA) and Delphi (Hologic). Body composition was first measured by the Hologic QDR-2000 and next by the Delphi W within 30 days in 99 healthy subjects. Whole-body fat mass (FM), percentage of FM, arm FM, and leg FM measured by the Hologic QDR-2000 were significantly larger than those measured by the Delphi W. Lean tissue mass (LTM), bone mineral content, and bone mineral density of the whole body, trunk FM, arm LTM, and leg LTM measured by the QDR-2000 were significantly smaller than those measured by the Delphi W. After converting the QDR-2000 values by equations developed by multiple regression analysis, they were not significantly different from the corresponding Delphi values. Measurements by the QDR-2000 and the Delphi W were not interchangeable and the conversion equations reduced the discrepancy to a level that enabled direct comparison of the data obtained by the two instruments. However, cautious interpretation is necessary when the conversion equations are applied to other instruments even of the same type or when evaluating data of individual subjects.

Mesh:

Year:  2006        PMID: 16785080     DOI: 10.1016/j.jocd.2006.03.008

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.617


  5 in total

1.  Operational definitions of sarcopenia and their associations with 5-year changes in falls risk in community-dwelling middle-aged and older adults.

Authors:  D Scott; A Hayes; K M Sanders; D Aitken; P R Ebeling; G Jones
Journal:  Osteoporos Int       Date:  2013-06-26       Impact factor: 4.507

2.  Bone cross-sectional geometry in adolescents and young women with anorexia nervosa: a hip structural analysis study.

Authors:  A D DiVasta; T J Beck; M A Petit; H A Feldman; M S LeBoff; C M Gordon
Journal:  Osteoporos Int       Date:  2007-01-05       Impact factor: 4.507

3.  Development and cross-validation of predictive equations for fat-free mass and lean soft tissue mass by bioelectrical impedance in Brazilian women.

Authors:  Roberto Fernandes da Costa; Kalina Veruska da Silva Bezerra Masset; Analiza M Silva; Breno Guilherme de Araújo Tinoco Cabral; Paulo Moreira Silva Dantas
Journal:  Eur J Clin Nutr       Date:  2021-07-06       Impact factor: 4.016

4.  Validation of dual energy X-ray absorptiometry measures of abdominal fat by comparison with magnetic resonance imaging in an Indian population.

Authors:  Amy E Taylor; Hannah Kuper; Ravi D Varma; Jonathan C Wells; Jimmy D Bell; K V Radhakrishna; Bharati Kulkarni; Sanjay Kinra; Nicholas J Timpson; Shah Ebrahim; George Davey Smith; Yoav Ben-Shlomo
Journal:  PLoS One       Date:  2012-12-14       Impact factor: 3.240

5.  Assessment of body composition in Indian adults: comparison between dual-energy X-ray absorptiometry and isotope dilution technique.

Authors:  Bharati Kulkarni; Hannah Kuper; Amy Taylor; Jonathan C Wells; K V Radhakrishna; Sanjay Kinra; Yoav Ben-Shlomo; George Davey Smith; Shah Ebrahim; A V Kurpad; Nuala M Byrne; Andrew P Hills
Journal:  Br J Nutr       Date:  2014-08-11       Impact factor: 3.718

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.