Literature DB >> 16784639

[Anatomic evaluation the entry point of C2 pedicle screw].

Xiang-yang Ma1, Qing-shui Yin, Zeng-hui Wu, Hong Xia, Shi-zhen Zhong, Jing-fa Liu, Da-chuan Xu.   

Abstract

OBJECTIVE: To study the relevant position of C(2) pedicle to C(2) inferior articular process, set up a technique of C(2) pedicle screw placement with the inferior articular process of axis as an anatomic landmark.
METHODS: Fifty C(2) bone specimens were used to measure the distance from the sagittal midline to the medial border, the midpoint and the lateral border of C(2) inferior articular process or C(2) pedicle; the width and the height of the C(2) pedicle were also evaluated. The anatomic relation between the measurements data of C(2) pedicle and that of C(2) inferior articular process were analyzed, and the technique of C(2) pedicle screw fixation was established.
RESULTS: The medial border of C(2) inferior articular process was averaged (3.67 +/- 0.41) mm lateral to that of C(2) pedicle, and the midpoint C(2) inferior articular process was averaged (1.15 +/- 0.44) mm lateral to the lateral border of C(2) pedicle, respectively. Using the C(2) inferior articular process as landmark, two techniques was established for C(2) pedicle screw placement. The entry point of method A was located in 2 mm medial and superior to the central point of C(2) inferior articular process; the entry point of method B was at the crossing point of the medial border C(2) inferior articular process with the superior quarter of C(2) inferior articular process.
CONCLUSIONS: There is a steady anatomic relation between C(2) pedicle and C(2) inferior articular process, the C(2) inferior articular process could be as a convenient key anatomic landmark to determine the location of C(2) pedicle and the position of C(2) pedicle screw entry point.

Entities:  

Mesh:

Year:  2006        PMID: 16784639

Source DB:  PubMed          Journal:  Zhonghua Wai Ke Za Zhi        ISSN: 0529-5815


  2 in total

1.  Morphological character of cervical spine for anterior transpedicular screw fixation.

Authors:  Rong-Ping Zhou; Jian Jiang; Zi-Chun Zhan; Yang Zhou; Zhi-Li Liu; Qing-Shui Yin
Journal:  Indian J Orthop       Date:  2013-11       Impact factor: 1.251

2.  The effectiveness and safety of 3-dimensional printed composite guide plate for atlantoaxial pedicle screw: A retrospective study.

Authors:  Fei Wang; Chang-Hong Li; Zhi-Bin Liu; Zhang-Jian Hua; Yong-Jin He; Jun Liu; Yan-Xiong Liu; Xiao-Qian Dang
Journal:  Medicine (Baltimore)       Date:  2019-01       Impact factor: 1.889

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.