Literature DB >> 16784425

The different ablation effects on atrioventricular nodal reentrant tachycardia in children with and without dual nodal pathways.

Pi-Chang Lee1, Betau Hwang, Ching-Tai Tai, Chern-En Chiang, Shih-Ann Chen.   

Abstract

BACKGROUND: Previous studies in adults have shown a significant shortening of the fast pathway effective refractory period (ERP) after successful slow pathway ablation. However, information on atrioventricular nodal reentrant tachycardia (AVNRT) in children is limited. The purpose of this retrospective study was to investigate the different effects of radiofrequency (RF) catheter ablation in pediatric AVNRT patients between those with and without dual atrioventricular (AV) nodal pathways.
METHODS: From January 1992 to August 2004, a total 67 pediatric patients with AVNRT underwent an electrophysiologic study and RF catheter ablation at our institution. We compared the electrophysiologic characteristics between those obtained before and after ablation in the children with AVNRT with and without dual AV nodal pathways.
RESULTS: Dual AV nodal pathways were found in 37 (55%) of 67 children, including 36 (54%) with antegrade and 10 (15%) with retrograde dual AV nodal pathways. The antegrade and retrograde fast pathway ERPs in children with dual AV nodal pathways were both longer than the antegrade and retrograde ERPs in children without dual AV nodal pathways (300 +/- 68 vs 264 +/- 58 ms, P = 0.004; 415 +/- 70 vs 250 +/- 45 ms, P < 0.001) before ablation. In children with antegrade dual AV nodal pathways, the antegrade fast pathway ERP decreased from 300 +/- 68 ms to 258 +/- 62 ms (P = 0.008). The retrograde fast pathway ERP also decreased after successful ablation in the children with retrograde dual AV nodal pathways (415 +/- 70 vs. 358 +/- 72 ms, P = 0.026).
CONCLUSION: The dual AV nodal physiology could not be commonly demonstrated in pediatric patients with inducible AVNRT. After a successful slow pathway ablation, the fast pathway ERP shortened significantly in the children with dual AV nodal pathways.

Entities:  

Mesh:

Year:  2006        PMID: 16784425     DOI: 10.1111/j.1540-8159.2006.00406.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  1 in total

1.  Electrophysiological changes in the conducting properties of fast pathway following modification of the slow pathway of the atrio ventricular node for atrio ventricular nodal re-entrant tachycardia.

Authors:  Imran Khan; Bakhtawar Shah
Journal:  Pak J Med Sci       Date:  2019 Sep-Oct       Impact factor: 1.088

  1 in total