Literature DB >> 16783717

Comparison of biochemical values in serum and plasma, fresh and frozen plasma, and hemolyzed samples from orange-winged Amazon parrots (Amazona amazonica).

Michelle G Hawkins1, Philip H Kass, Joseph G Zinkl, Lisa A Tell.   

Abstract

BACKGROUND: To the authors' knowledge, on the basis of sample type, storage condition, or hemolysis, differences in serum and plasma biochemical values have not been evaluated in orange-winged Amazon parrots (Amazona amazonica).
OBJECTIVES: The purpose of this study was to compare values for biochemical analytes in serum vs plasma, fresh vs frozen plasma, and nonhemolyzed vs hemolyzed samples in orange-winged Amazon parrots. We also compared differences in serum and plasma yield from whole-blood aliquots.
METHODS: Fifteen biochemical analytes were evaluated in paired serum and plasma, fresh and frozen plasma, nonhemolyzed and hemolyzed serum and plasma samples from orange-winged Amazon parrots (n = 10) using a wet reagent analyzer. Hemolysis was assessed qualitatively (visually) and quantitatively (hemoglobin [Hgb] measured spectrophotometrically). Serum and plasma yields from 500-microl whole-blood aliquots were determined from centrifuged samples.
RESULTS: Analyte values significantly differed among sample groups, but were still within published reference intervals, with the exception of increases in potassium concentration in markedly hemolyzed serum and plasma samples. Clinically important changes in hemolyzed serum and plasma samples included increases in potassium, phosphorus, and albumin concentrations and lactate dehydrogenase activity. The degree of hemolysis assigned qualitatively did not correlate with quantitative Hgb concentration. A significantly greater yield of plasma (288 +/- 13 microL) than serum (241 +/- 44 microL) was obtained.
CONCLUSIONS: Significant differences may occur in different sample types, however, only changes in potassium, phosphorus, albumin, and lactate dehydrogenase values in hemolyzed samples were considered clinically relevant. Lack of agreement between qualitative and quantitative Hgb concentration indicates the unreliability of visual estimation. Based on higher sample yield, and lack of clinically relevant differences from serum, plasma is a better sample choice for clinical chemistry analysis in birds.

Entities:  

Mesh:

Year:  2006        PMID: 16783717     DOI: 10.1111/j.1939-165x.2006.tb00118.x

Source DB:  PubMed          Journal:  Vet Clin Pathol        ISSN: 0275-6382            Impact factor:   1.180


  4 in total

1.  Effects of storage temperature and time on clinical biochemical parameters from rat serum.

Authors:  Carolyn Cray; Marilyn Rodriguez; Julia Zaias; Norman H Altman
Journal:  J Am Assoc Lab Anim Sci       Date:  2009-03       Impact factor: 1.232

2.  Effect of storage time and temperature on the total protein concentration and electrophoretic fractions in equine serum.

Authors:  Daniela Alberghina; Stefania Casella; Claudia Giannetto; Simona Marafioti; Giuseppe Piccione
Journal:  Can J Vet Res       Date:  2013-10       Impact factor: 1.310

3.  Influence of heat stress on reference genes stability in heart and liver of two chickens genotypes.

Authors:  Juliana Gracielle Gonzaga Gromboni; Haniel Cedraz de Oliveira; Daniele Botelho Diniz Marques; Antônio Amândio Pinto Garcia Junior; Ronaldo Vasconcelos Farias Filho; Caio Fernando Gromboni; Teillor Machado Souza; Amauri Arias Wenceslau
Journal:  PLoS One       Date:  2020-02-06       Impact factor: 3.240

4.  Plasma chemistry in nesting leatherback sea turtles (Dermochelys coriacea) from Florida: Understanding the importance of sample hemolysis effects on blood analytes.

Authors:  Nicole I Stacy; Ryan M Chabot; Charles J Innis; Carolyn Cray; Katelyn M Fraser; Kimberly S Rigano; Justin R Perrault
Journal:  PLoS One       Date:  2019-09-10       Impact factor: 3.240

  4 in total