Literature DB >> 16783431

Filter for biomedical imaging and image processing.

Partha P Mondal1, K Rajan, Imteyaz Ahmad.   

Abstract

Image filtering techniques have numerous potential applications in biomedical imaging and image processing. The design of filters largely depends on the a priori, knowledge about the type of noise corrupting the image. This makes the standard filters application specific. Widely used filters such as average, Gaussian, and Wiener reduce noisy artifacts by smoothing. However, this operation normally results in smoothing of the edges as well. On the other hand, sharpening filters enhance the high-frequency details, making the image nonsmooth. An integrated general approach to design a finite impulse response filter based on Hebbian learning is proposed for optimal image filtering. This algorithm exploits the interpixel correlation by updating the filter coefficients using Hebbian learning. The algorithm is made iterative for achieving efficient learning from the neighborhood pixels. This algorithm performs optimal smoothing of the noisy image by preserving high-frequency as well as low-frequency features. Evaluation results show that the proposed finite impulse response filter is robust under various noise distributions such as Gaussian noise, salt-and-pepper noise, and speckle noise. Furthermore, the proposed approach does not require any a priori knowledge about the type of noise. The number of unknown parameters is few, and most of these parameters are adaptively obtained from the processed image. The proposed filter is successfully applied for image reconstruction in a positron emission tomography imaging modality. The images reconstructed by the proposed algorithm are found to be superior in quality compared with those reconstructed by existing PET image reconstruction methodologies.

Mesh:

Year:  2006        PMID: 16783431     DOI: 10.1364/josaa.23.001678

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  2 in total

1.  Quantitative evaluation of skeletal muscle defects in second harmonic generation images.

Authors:  Wenhua Liu; Nina Raben; Evelyn Ralston
Journal:  J Biomed Opt       Date:  2013-02       Impact factor: 3.170

2.  Adaptive noise reduction of scintigrams with a wavelet transform.

Authors:  Koichi Ogawa; Masahiko Sakata; Yu Li
Journal:  Int J Biomed Imaging       Date:  2012-02-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.