Literature DB >> 16779771

Determination of S-phenylmercapturic acid in human urine using an automated sample extraction and fast liquid chromatography-tandem mass spectrometric method.

Yinghe Li1, Austin C Li, Haihong Shi, Heiko Junga, Xiangyu Jiang, Weng Naidong, John H Lauterbach.   

Abstract

S-phenylmercapturic acid is widely accepted as a specific biomarker for the evaluation of benzene exposure. Here, we describe a fast, specific and sensitive high-performance liquid achromatography coupled with tandem mass spectrometry (LC-MS/MS) method that has been developed and validated for the determination of S-phenylmercapturic acid in human urine. Isotope-labeled S-phenylmercapturic acid-d5 was used as internal standard to improve the method ruggedness. The fully automated solid-phase extraction method on a 96-well Oasis MAX (mix-mode anion exchange) plate was employed to clean up the urine samples before analysis. The rapid LC-MS/MS analysis of extracted samples was achieved on a Genesis C18 column with a run time of only 3 min. Negative electrospray ionization with multiple reaction monitoring (ESI-MRM) mode was used to detect S-phenylmercapturic acid (m/z 238 --> 109) and S-phenylmercapturic acid -d5 (m/z 243 --> 114). The method fulfils all the standard requirements of method validation. The calibration curve was linear within the concentration range 0.400-200 ng/mL. The method performed accurately and precisely in validation with <7.5% relative error and <6.5% relative standard deviation of quality control samples. The method efficacy was also verified by the analysis of urine samples from 12 smokers and 12 non-smokers. With the fully automated sample cleanup procedure and the fast LC-MS/MS analysis, a sample analysis throughput of 384 samples per day could be achieved. Copyright 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16779771     DOI: 10.1002/bmc.653

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  3 in total

1.  (2-methoxyethoxy)acetic acid: a urinary biomarker of exposure for jet fuel JP-8.

Authors:  Clayton B'hymer; Patricia Mathias; Edward Krieg; Kenneth L Cheever; Christine A Toennis; John C Clark; James S Kesner; Roger L Gibson; Mary Ann Butler
Journal:  Int Arch Occup Environ Health       Date:  2011-08-02       Impact factor: 3.015

Review 2.  Benzene exposure: an overview of monitoring methods and their findings.

Authors:  Clifford P Weisel
Journal:  Chem Biol Interact       Date:  2010-01-06       Impact factor: 5.192

Review 3.  A survey of liquid chromatographic-mass spectrometric analysis of mercapturic acid biomarkers in occupational and environmental exposure monitoring.

Authors:  Patricia I Mathias; Clayton B'Hymer
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2014-03-12       Impact factor: 3.205

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.