Literature DB >> 16772689

Mercury(II) ion-selective polymeric membrane sensors for analysis of mercury in hazardous wastes.

Saad S M Hassan1, W H Mahmoud, Ayman H K Mohamed, Ali E Kelany.   

Abstract

Two novel potentiometric sensors that are highly selective to Hg2+ ions are described. These are based on the use of 5,5'-dithio-bis(2-nitrobenzoic acid) (DTNB) and tricyclazole (TCZ) as neutral carriers in plasticized poly(vinyl chloride) membranes. Fast Nernstian responses are obtained for Hg2+ ions over the concentration ranges 7.0 x 10(-6) - 1.0 x 10(-2) and 7.7 x 10(-6) - 1.0 x 10(-2) mol l(-1) at pH 1.8 - 3.3 with lower detection limits of 5.0 x 10(-6) and 5.6 x 10(-6) mol l(-1) (approximately 1 microh ml(-1)) and calibration slopes of 30.0 and 29.7 mV decade(-1) with DTNB- and TCZ-based membrane sensors, respectively. Validation of the assay method reveals good performance characteristics, including long life span, good selectivity for Hg2+ ions over a wide variety of other metal ions, long term response stability, and high reproducibility. Applications for direct determination of mercury in hazardous wastes including dental amalgam, mercury bulbs, and fluorescent lamps give results with good correlation with data obtained using cold vapor atomic absorption spectrometry.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16772689     DOI: 10.2116/analsci.22.877

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  6 in total

1.  All-Solid-State Potentiometric Platforms Modified with a Multi-Walled Carbon Nanotubes for Fluoxetine Determination.

Authors:  Hisham S M Abd-Rabboh; Heba M Hashem; Layla M S Al Shagri; Abdel El-Galil E Amr; Abdulrahman A Almehizia; Ahmed M Naglah; Ayman H Kamel
Journal:  Membranes (Basel)       Date:  2022-04-21

Review 2.  Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade.

Authors:  Farnoush Faridbod; Parviz Norouzi; Rassoul Dinarvand; Mohammad Reza Ganjali
Journal:  Sensors (Basel)       Date:  2008-04-03       Impact factor: 3.576

3.  Novel Solid-State Potentiometric Sensors Using Polyaniline (PANI) as A Solid-Contact Transducer for Flucarbazone Herbicide Assessment.

Authors:  Ayman H Kamel; Abd El-Galil E Amr; Nashwa S Abdalla; Mohamed El-Naggar; Mohamed A Al-Omar; Hamad M Alkahtani; Ahmed Y A Sayed
Journal:  Polymers (Basel)       Date:  2019-11-01       Impact factor: 4.329

4.  Novel Potentiometric 2,6-Dichlorophenolindo-phenolate (DCPIP) Membrane-Based Sensors: Assessment of Their Input in the Determination of Total Phenolics and Ascorbic Acid in Beverages.

Authors:  Nada H A Elbehery; Abd El-Galil E Amr; Ayman H Kamel; Elsayed A Elsayed; Saad S M Hassan
Journal:  Sensors (Basel)       Date:  2019-05-02       Impact factor: 3.576

5.  Potentiometric PVC-Membrane-Based Sensor for Dimethylamine Assessment Using A Molecularly Imprinted Polymer as A Sensory Recognition Element.

Authors:  Saad S M Hassan; Abd El-Galil E Amr; Heba Abd El-Naby; Mohamed A Al-Omar; Ayman H Kamel; Nagy M Khalifa
Journal:  Polymers (Basel)       Date:  2019-10-16       Impact factor: 4.329

6.  Novel Validated Analytical Method Based on Potentiometric Transduction for the Determination of Citicoline Psychostimulant/Nootropic Agent.

Authors:  Ayman H Kamel; Abd El-Galil E Amr; Hoda R Galal; Abdulrahman A Almehizia
Journal:  Molecules       Date:  2020-07-31       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.