Data consistency based translational motion artifact reduction in fan-beam CT.

Hengyong Yu1, Yuchuan Wei, Jiang Hsieh, Ge Wang.   

Abstract

A basic assumption in the classic computed tomography (CT) theory is that an object remains stationary in an entire scan. In biomedical CT/micro-CT, this assumption is often violated. To produce high-resolution images, such as for our recently proposed clinical micro-CT (CMCT) prototype, it is desirable to develop a precise motion estimation and image reconstruction scheme. In this paper, we first extend the Helgason-Ludwig consistency condition (HLCC) from parallel-beam to fan-beam geometry when an object is subject to a translation. Then, we propose a novel method to estimate the motion parameters only from sinograms based on the HLCC. To reconstruct the moving object, we formulate two generalized fan-beam reconstruction methods, which are in filtered backprojection and backprojection filtering formats, respectively. Furthermore, we present numerical simulation results to show that our approach is accurate and robust.

Mesh:

Year:  2006        PMID: 16768243     DOI: 10.1109/tmi.2006.875424

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Motion compensation for cone-beam CT using Fourier consistency conditions.

Authors:  M Berger; Y Xia; W Aichinger; K Mentl; M Unberath; A Aichert; C Riess; J Hornegger; R Fahrig; A Maier
Journal:  Phys Med Biol       Date:  2017-08-21       Impact factor: 3.609

2.  Ultra-low dose lung CT perfusion regularized by a previous scan.

Authors:  Hengyong Yu; Shiying Zhao; Eric A Hoffman; Ge Wang
Journal:  Acad Radiol       Date:  2009-03       Impact factor: 3.173

3.  Study of the Microfocus X-Ray Tube Based on a Point-Like Target Used for Micro-Computed Tomography.

Authors:  Rifeng Zhou; Xiaojian Zhou; Xiaobin Li; Yufang Cai; Fenglin Liu
Journal:  PLoS One       Date:  2016-06-01       Impact factor: 3.240

4.  An Improved Extrapolation Scheme for Truncated CT Data Using 2D Fourier-Based Helgason-Ludwig Consistency Conditions.

Authors:  Yan Xia; Martin Berger; Sebastian Bauer; Shiyang Hu; Andre Aichert; Andreas Maier
Journal:  Int J Biomed Imaging       Date:  2017-07-20

5.  Correction of center of rotation and projection angle in synchrotron X-ray computed tomography.

Authors:  Chang-Chieh Cheng; Yu-Tai Ching; Pai-Hung Ko; Yeukuang Hwu
Journal:  Sci Rep       Date:  2018-06-29       Impact factor: 4.379