A numerical study on the effect of side hole number and arrangement in venous cannulae.

J Y Park1, C Y Park, B G Min.   

Abstract

Insertion of cannulae into vessels may apply non-physiological load and stress on blood cells, such that adenosine diphosphate may increase and result in hemolysis. Authors used the computational method to simulate the blood flow inside of the cannula. We limited the research to within the drainage cannulae. Nine different cannulae categorized by the number of side holes of 4, 12, and 20, and also categorized by the array type as staggered array, in-line array, and alternative in-line array were studied and compared to the cannulae with no side holes by using computational fluid dynamics. We evaluated the flow rate, the wall shear stress, and the shear rate, and compared them with one another to estimate the effect of the side holes. The flow rate is not proportional to the number of the side holes. However, larger number of side holes can reduce the mean shear rate.

Entities:  

Mesh:

Year:  2006        PMID: 16764882     DOI: 10.1016/j.jbiomech.2006.04.005

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Influence of contrast-enhanced ultrasound administration setups on microbubble enhancement: a focus on pediatric applications.

Authors:  Michael R Kramer; Nishi Bhagat; Susan J Back; Laura Poznick; Flemming Forsberg; Kassa Darge; John R Eisenbrey
Journal:  Pediatr Radiol       Date:  2017-09-11

2.  Computational fluid dynamics analysis of thrombosis potential in left ventricular assist device drainage cannulae.

Authors:  Katharine H Fraser; Tao Zhang; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  ASAIO J       Date:  2010 May-Jun       Impact factor: 2.872

3.  The need of slanted side holes for venous cannulae.

Authors:  Joong Yull Park
Journal:  Comput Math Methods Med       Date:  2012-01-12       Impact factor: 2.238

4.  Impact of cannula design on packed red blood cell transfusions: technical advancement to improve outcomes in extracorporeal membrane oxygenation.

Authors:  Gennaro Martucci; Giovanna Panarello; Giovanna Occhipinti; Giuseppe Raffa; Fabio Tuzzolino; Guido Capitanio; Tiziana Carollo; Giovanni Lino; Alessandro Bertani; Patrizio Vitulo; Michele Pilato; Roberto Lorusso; Antonio Arcadipane
Journal:  J Thorac Dis       Date:  2018-10       Impact factor: 2.895

5.  More holes, more contrast? Comparing an 18-gauge non-fenestrated catheter with a 22-gauge fenestrated catheter for cardiac CT.

Authors:  Andreas Marco Fischer; Philipp Riffel; Thomas Henzler; U Joseph Schoepf; Andres F Abadia; Richard Robert Bayer; Holger Haubenreisser; Dante Giovagnoli; Alexander Kremer; Stefan O Schoenberg; Joshua Gawlitza
Journal:  PLoS One       Date:  2020-06-08       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.