| Literature DB >> 1676204 |
J M Degroodt1, B Wyhowski de Bukanski, J De Groof, H Beernaert.
Abstract
A method has been developed for the analysis of cimaterol and clenbuterol residues in liver, with detection limits of 0.25 micrograms/kg and 0.5 micrograms/kg, respectively. The recovery varied from 55% to 60%. After extraction, a clean-up procedure with Baker-spe C-18 columns was performed. The two chemical compounds of interest were eluted with methanol. Cimaterol and clenbuterol were quantitatively determined by high-performance liquid chromatography (HPLC) using an RP-Select B (5 microns) column and a post-column reaction procedure. The positive results were confirmed by high-performance thin-layer chromatography (HPTLC) as this technique reaches the same level of sensitivity as the HPLC method.Entities:
Mesh:
Substances:
Year: 1991 PMID: 1676204 DOI: 10.1007/bf01193142
Source DB: PubMed Journal: Z Lebensm Unters Forsch ISSN: 0044-3026