Development of an implantable oxygenator with cross-flow pump.

Yuichi Asakawa1, Akio Funakubo, Kazuyoshi Fukunaga, Ichiro Taga, Tetsuya Higami, Tsuyoshi Kawamura, Yasuhiro Fukui.   

Abstract

Thrombogenicity, a problem with long-term artificial lungs, is caused by blood-biomaterial interactions and is made worse by nonuniform flow, which also causes decreased gas exchange. To overcome these obstacles, we changed the inlet and added a uniform flow pump to our previous oxygenator design. Conventional membrane oxygenators have a (1/2)-inch port for the inlet of blood. These port structures make it difficult for the blood to flow uniformly in the oxygenator. In addition, the complex blood flow patterns that occur in the oxygenator, including turbulence and stagnation, lead to thrombogenicity. A cross-flow pump (CFP) can result in uniform blood flow to the inlet side of an oxygenator. In this study, we evaluated the usefulness of an integrated oxygenator with a fiber bundle porosity of 0.6 and a membrane surface area of 1.3 m2. The inlet part of the oxygenator is improved and better fits the outlet of the CFP. Each of the three models of the improved oxygenator has a different inlet taper angle. The computational fluid dynamics analysis showed that, compared with the original design, uniform flow of the integrated oxygenator improved by 88.8% at the hollow fiber membrane. With the integrated oxygenator, O2 transfer increased by an average of 20.8%, and CO2 transfer increased by an average of 35.5%. The results of our experiments suggest that the CFP, which produces a wide, uniform flow to the oxygenator, is effective in attaining high gas exchange performance.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16760718     DOI: 10.1097/01.mat.0000216165.21432.ee

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

Review 1.  Artificial lungs: current state and trends of clinical use and research and development.

Authors:  Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2007-03-23       Impact factor: 1.731

2.  Thirty-day in-vivo performance of a wearable artificial pump-lung for ambulatory respiratory support.

Authors:  Zhongjun J Wu; Tao Zhang; Giacomo Bianchi; Xufeng Wei; Ho-Sung Son; Kang Zhou; Pablo G Sanchez; Jose Garcia; Bartley P Griffith
Journal:  Ann Thorac Surg       Date:  2011-11-25       Impact factor: 4.330

3.  Microchannel technologies for artificial lungs: (2) screen-filled wide rectangular channels.

Authors:  M C Kung; J-K Lee; H H Kung; L F Mockros
Journal:  ASAIO J       Date:  2008 Jul-Aug       Impact factor: 2.872