Literature DB >> 16758000

Accuracy Evaluation for Region Centroid-Based Registration of Fluorescent CLSM Imagery.

Sang-Chul Lee, Peter Bajcsy, Amy Lin, Robert Folberg.   

Abstract

We present an accuracy evaluation of a semi-automatic registration technique for 3D volume reconstruction from fluorescent confocal laser scanning microscope (CLSM) imagery. The presented semi-automatic method is designed based on our observations that (a) an accurate point selection is much harder than an accurate region (segment) selection for a human, (b) a centroid selection of any region is less accurate by a human than by a computer, and (c) registration based on structural shape of a region rather than based on intensity-defined point is more robust to noise and to morphological deformation of features across stacks. We applied the method to image mosaicking and image alignment registration steps and evaluated its performance with 20 human subjects on CLSM images with stained blood vessels. Our experimental evaluation showed significant benefits of automation for 3D volume reconstruction in terms of achieved accuracy, consistency of results and performance time. In addition, the results indicate that the differences between registration accuracy obtained by experts and by novices disappear with the proposed semi-automatic registration technique while the absolute registration accuracy increases.

Entities:  

Year:  2006        PMID: 16758000      PMCID: PMC1474139          DOI: 10.1155/ASP/2006/82480

Source DB:  PubMed          Journal:  EURASIP J Appl Signal Processing        ISSN: 1110-8657


  5 in total

Review 1.  Medical image registration.

Authors:  D L Hill; P G Batchelor; M Holden; D J Hawkes
Journal:  Phys Med Biol       Date:  2001-03       Impact factor: 3.609

Review 2.  A survey of medical image registration.

Authors:  J B Maintz; M A Viergever
Journal:  Med Image Anal       Date:  1998-03       Impact factor: 8.545

3.  Tissue microarrays (TMAs) for high-throughput molecular pathology research.

Authors:  A Nocito; J Kononen; O P Kallioniemi; G Sauter
Journal:  Int J Cancer       Date:  2001-10-01       Impact factor: 7.396

4.  A contour-based approach to multisensor image registration.

Authors:  H Li; B S Manjunath; S K Mitra
Journal:  IEEE Trans Image Process       Date:  1995       Impact factor: 10.856

5.  Laser scanning confocal microscopy for in situ monitoring of alkali-silica reaction.

Authors:  C L Collins; J H Ideker; K E Kurtis
Journal:  J Microsc       Date:  2004-02       Impact factor: 1.758

  5 in total
  4 in total

1.  3D medical volume reconstruction using web services.

Authors:  Rob Kooper; Andrew Shirk; Sang-Chul Lee; Amy Lin; Robert Folberg; Peter Bajcsy
Journal:  Comput Biol Med       Date:  2008-03-11       Impact factor: 4.589

2.  Accurate image rotation using hermite expansions.

Authors:  Wooram Park; Gregory Leibon; Daniel N Rockmore; Gregory S Chirikjian
Journal:  IEEE Trans Image Process       Date:  2009-06-05       Impact factor: 10.856

3.  M3G: maximum margin microarray gridding.

Authors:  Dimitris Bariamis; Dimitris K Iakovidis; Dimitris Maroulis
Journal:  BMC Bioinformatics       Date:  2010-01-25       Impact factor: 3.169

4.  A Combinational Clustering Based Method for cDNA Microarray Image Segmentation.

Authors:  Guifang Shao; Tiejun Li; Wangda Zuo; Shunxiang Wu; Tundong Liu
Journal:  PLoS One       Date:  2015-08-04       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.