Literature DB >> 16755828

Automated interpretation of regional left ventricular wall motion from cardiac magnetic resonance images.

Enrico G Caiani1, Eran Toledo, Peter MacEneaney, Dianna Bardo, Sergio Cerutti, Roberto M Lang, Victor Mor-Avi.   

Abstract

UNLABELLED: Magnetic resonance (MR) diagnosis of regional left ventricular (LV) dysfunction relies on visual interpretation of cine images that suffers from wide inter-observer variability, especially when performed by readers not specifically trained in the assessment of LV wall motion. Quantitative analysis tools, though widely available, are rarely used because they provide large amounts of detailed information, the interpretation of which requires additional time-consuming processing. We tested the feasibility of fast automated interpretation of regional LV function using computer analysis of this wall motion information.
METHODS: Dynamic, ECG-gated, steady-state free precession short-axis images were obtained in 6-10 slices in 28 subjects (10 normal volunteers; 18 patients). Images were reviewed by an expert cardiologist who provided "gold standard" grades (normal, abnormal) for regional wall motion and, independently, by four radiologists. Same images were then analyzed using custom software. Regional fractional area changes computed in normal volunteers were used to obtain the optimal segment- and slice-specific threshold values for automated classification of regional wall motion for each patient. The levels of agreement with the "gold standard" grades were compared between the radiologists and the automated interpretation.
RESULTS: While the visual interpretation required 2-5 minute per patient, the automated interpretation required < 1 sec, after endocardial border detection was complete. The automated interpretation resulted in higher sensitivity, specificity, and accuracy (84%, 77%, 79%, respectively) than the radiologists' grades (80%, 76%, 77%, respectively) and eliminated the high interobserver variability.
CONCLUSION: Once the endocardial boundaries are defined, computer analysis of the regional wall motion information allows accurate, fully automated, immediate, objective and experience-independent interpretation of regional LV function.

Entities:  

Mesh:

Year:  2006        PMID: 16755828     DOI: 10.1080/10976640600599486

Source DB:  PubMed          Journal:  J Cardiovasc Magn Reson        ISSN: 1097-6647            Impact factor:   5.364


  5 in total

1.  Volumetric analysis of regional left ventricular function with real-time three-dimensional echocardiography: validation by magnetic resonance and clinical utility testing.

Authors:  Hans Jaochim Nesser; Lissa Sugeng; Cristiana Corsi; Lynn Weinert; Johannes Niel; Christian Ebner; Regina Steringer-Mascherbauer; Frank Schmidt; Georg Schummers; Roberto M Lang; Victor Mor-Avi
Journal:  Heart       Date:  2006-09-15       Impact factor: 5.994

2.  Interpretation of cardiac wall motion from cine-MRI combined with parametric imaging based on the Hilbert transform.

Authors:  Narjes Benameur; Enrico Gianluca Caiani; Younes Arous; Nejmeddine Ben Abdallah; Tarek Kraiem
Journal:  MAGMA       Date:  2017-02-20       Impact factor: 2.310

3.  Evaluation of Left Ventricle Function by Regional Fractional Area Change (RFAC) in a Mouse Model of Myocardial Infarction Secondary to Valsartan Treatment.

Authors:  Laura Castiglioni; Francesca Colazzo; Lucia Fontana; Gualtiero I Colombo; Luca Piacentini; Elisa Bono; Giuseppina Milano; Serena Paleari; Annamaria Palermo; Uliano Guerrini; Elena Tremoli; Luigi Sironi
Journal:  PLoS One       Date:  2015-08-20       Impact factor: 3.240

4.  Detection of Cardiac Function Abnormality from MRI Images Using Normalized Wall Thickness Temporal Patterns.

Authors:  Mai Wael; El-Sayed H Ibrahim; Ahmed S Fahmy
Journal:  Int J Biomed Imaging       Date:  2016-03-01

5.  Right ventricular (RV) echocardiographic parameters in patients with pulmonary thromboembolism (PTE).

Authors:  Javad Shahabi; Reihaneh Zavar; Afshin Amirpour; Mohammad Bidmeshki; Melinaz Barati-Chermahini
Journal:  ARYA Atheroscler       Date:  2018-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.