PURPOSE: To assess the feasibility of using phase contrast magnetic resonance (PC-MR) imaging to measure the change in collateral blood flow early after stenting of aortic coarctation. MATERIALS AND METHODS: A total of 10 consecutive patients with coarctation of the aorta underwent MR imaging, X-ray angiography, and stent placement. PC-MR at two sites in the descending aorta was performed before and early after stenting in order to estimate collateral inflow to the descending thoracic aorta. The collateral flow and collateral flow percentage before and after stent placement were compared. RESULTS: Before stenting, the mean proximal aortic flow = 43.9 +/- 14.6 mL/second; mean distal flow = 54.2 +/- 10 mL/second; collateral flow = 10.2 +/- 6.8 mL/second; and collateral flow percentage = 30.1 +/- 27.9%. After stenting, the mean proximal aortic flow = 62.1 +/- 17.9 mL/second; mean distal flow = 60 +/- 19 mL/second; collateral flow = -1.9 +/- 3.7 mL/second; and collateral flow percentage = -3.3 +/- 6.8%. CONCLUSION: PC-MR can be used to measure changes in collateral circulation after stent treatment of coarctation of the aorta. (c) 2006 Wiley-Liss, Inc.
PURPOSE: To assess the feasibility of using phase contrast magnetic resonance (PC-MR) imaging to measure the change in collateral blood flow early after stenting of aortic coarctation. MATERIALS AND METHODS: A total of 10 consecutive patients with coarctation of the aorta underwent MR imaging, X-ray angiography, and stent placement. PC-MR at two sites in the descending aorta was performed before and early after stenting in order to estimate collateral inflow to the descending thoracic aorta. The collateral flow and collateral flow percentage before and after stent placement were compared. RESULTS: Before stenting, the mean proximal aortic flow = 43.9 +/- 14.6 mL/second; mean distal flow = 54.2 +/- 10 mL/second; collateral flow = 10.2 +/- 6.8 mL/second; and collateral flow percentage = 30.1 +/- 27.9%. After stenting, the mean proximal aortic flow = 62.1 +/- 17.9 mL/second; mean distal flow = 60 +/- 19 mL/second; collateral flow = -1.9 +/- 3.7 mL/second; and collateral flow percentage = -3.3 +/- 6.8%. CONCLUSION: PC-MR can be used to measure changes in collateral circulation after stent treatment of coarctation of the aorta. (c) 2006 Wiley-Liss, Inc.
Authors: W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard Journal: Circulation Date: 2010-05-17 Impact factor: 29.690
Authors: W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard Journal: J Am Coll Cardiol Date: 2010-06-08 Impact factor: 24.094
Authors: Volker Rasche; Alexander Oberhuber; Stephan Trumpp; Axel Bornstedt; Karl-Heinz Orend; Nico Merkle; Wolfgang Rottbauer; Martin Hoffmann Journal: Eur Radiol Date: 2011-02-18 Impact factor: 5.315