Literature DB >> 16753210

Long-term maintenance of human hepatocytes in oxygen-permeable membrane bioreactor.

Loredana De Bartolo1, Simona Salerno, Sabrina Morelli, Lidietta Giorno, Maria Rende, Bruno Memoli, Alfredo Procino, Vittorio E Andreucci, Augustinus Bader, Enrico Drioli.   

Abstract

An oxygen-permeable membrane bioreactor utilizing human hepatocytes has been tested in this study. In the bioreactor, human hepatocytes were cultured between flat-sheet gas-permeable polymeric membranes, which ensure the diffusion of O(2) and CO(2) providing a support for cell anchorage and growth and permit the online observation of the cells with an inverse microscope. This bioreactor allows a direct oxygenation of cells adhered on membranes and of the medium overlaying cells simulating in vivo sinusoidal organization. Human hepatocytes were cultured in the presence of some therapeutic molecules to assess the temporal liver-specific functions of the cells. Interleukin 6 (IL-6), which is a multifactorial proinflammatory cytokine involved in a variety of host defences and pathological processes, and diclofenac, an arylacetic non-steroidal anti-inflammatory drug, were used as therapeutic molecules. The aim of this study was to evaluate the in vitro performance of the small oxygen-permeable membrane bioreactor in the long-term maintenance and differentiation of human hepatocytes under in-vivo-like conditions. The fluid dynamics of the bioreactor were characterized before using it for human cell culture. The functional response to a step challenge in the medium of IL-6 (120 pg/ml), diclofenac (80 microm) and IL-6 and diclofenac together was investigated. The ability of hepatocytes to perform liver-specific functions in terms of urea and albumin synthesis, as well as secretion of total proteins, was maintained for 32 days. Also, the diclofenac biotransformation functions were sustained as the formation of the metabolites 4'-OH-diclofenac and 5-OH-diclofenac lactam demonstrated. This study attested the feasibility of the membrane bioreactor as an in vitro simple model system that allows human hepatocytes to be maintained in a differentiated state similar to that in vivo.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16753210     DOI: 10.1016/j.biomaterials.2006.05.015

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  14 in total

1.  The effectiveness of a novel cartridge-based bioreactor design in supporting liver cells.

Authors:  Mei Niu; Paul Hammond; Robin N Coger
Journal:  Tissue Eng Part A       Date:  2009-10       Impact factor: 3.845

Review 2.  Strategies for improving the physiological relevance of human engineered tissues.

Authors:  Rosalyn D Abbott; David L Kaplan
Journal:  Trends Biotechnol       Date:  2015-04-30       Impact factor: 19.536

3.  Toxicity testing of four silver nanoparticle-coated dental castings in 3-D LO2 cell cultures.

Authors:  Yi-Ying Zhao; Qiang Chu; Xu-Er Shi; Xiao-Dong Zheng; Xiao-Ting Shen; Yan-Zhen Zhang
Journal:  J Zhejiang Univ Sci B       Date:  2018 Feb.       Impact factor: 3.066

Review 4.  Mesenchymal stromal cells as supportive cells for hepatocytes.

Authors:  Alejandro Gómez-Aristizábal; Armand Keating; John E Davies
Journal:  Mol Ther       Date:  2009-07-07       Impact factor: 11.454

5.  Microengineered cell and tissue systems for drug screening and toxicology applications: Evolution of in-vitro liver technologies.

Authors:  O B Usta; W J McCarty; S Bale; M Hegde; R Jindal; A Bhushan; I Golberg; M L Yarmush
Journal:  Technology (Singap World Sci)       Date:  2015-03

Review 6.  Bioreactor technologies to support liver function in vitro.

Authors:  Mohammad R Ebrahimkhani; Jaclyn A Shepard Neiman; Micha Sam B Raredon; David J Hughes; Linda G Griffith
Journal:  Adv Drug Deliv Rev       Date:  2014-03-05       Impact factor: 15.470

7.  Multi-cellular 3D human primary liver cell culture elevates metabolic activity under fluidic flow.

Authors:  Mandy B Esch; Jean-Matthieu Prot; Ying I Wang; Paula Miller; Jose Ricardo Llamas-Vidales; Brian A Naughton; Dawn R Applegate; Michael L Shuler
Journal:  Lab Chip       Date:  2015-05-21       Impact factor: 6.799

8.  Replica-moulded polydimethylsiloxane culture vessel lids attenuate osmotic drift in long-term cell cultures.

Authors:  Axel Blau; Tanja Neumann; Christiane Ziegler; Fabio Benfenati
Journal:  J Biosci       Date:  2009-03       Impact factor: 1.826

Review 9.  Recent advances in 2D and 3D in vitro systems using primary hepatocytes, alternative hepatocyte sources and non-parenchymal liver cells and their use in investigating mechanisms of hepatotoxicity, cell signaling and ADME.

Authors:  Patricio Godoy; Nicola J Hewitt; Ute Albrecht; Melvin E Andersen; Nariman Ansari; Sudin Bhattacharya; Johannes Georg Bode; Jennifer Bolleyn; Christoph Borner; Jan Böttger; Albert Braeuning; Robert A Budinsky; Britta Burkhardt; Neil R Cameron; Giovanni Camussi; Chong-Su Cho; Yun-Jaie Choi; J Craig Rowlands; Uta Dahmen; Georg Damm; Olaf Dirsch; María Teresa Donato; Jian Dong; Steven Dooley; Dirk Drasdo; Rowena Eakins; Karine Sá Ferreira; Valentina Fonsato; Joanna Fraczek; Rolf Gebhardt; Andrew Gibson; Matthias Glanemann; Chris E P Goldring; María José Gómez-Lechón; Geny M M Groothuis; Lena Gustavsson; Christelle Guyot; David Hallifax; Seddik Hammad; Adam Hayward; Dieter Häussinger; Claus Hellerbrand; Philip Hewitt; Stefan Hoehme; Hermann-Georg Holzhütter; J Brian Houston; Jens Hrach; Kiyomi Ito; Hartmut Jaeschke; Verena Keitel; Jens M Kelm; B Kevin Park; Claus Kordes; Gerd A Kullak-Ublick; Edward L LeCluyse; Peng Lu; Jennifer Luebke-Wheeler; Anna Lutz; Daniel J Maltman; Madlen Matz-Soja; Patrick McMullen; Irmgard Merfort; Simon Messner; Christoph Meyer; Jessica Mwinyi; Dean J Naisbitt; Andreas K Nussler; Peter Olinga; Francesco Pampaloni; Jingbo Pi; Linda Pluta; Stefan A Przyborski; Anup Ramachandran; Vera Rogiers; Cliff Rowe; Celine Schelcher; Kathrin Schmich; Michael Schwarz; Bijay Singh; Ernst H K Stelzer; Bruno Stieger; Regina Stöber; Yuichi Sugiyama; Ciro Tetta; Wolfgang E Thasler; Tamara Vanhaecke; Mathieu Vinken; Thomas S Weiss; Agata Widera; Courtney G Woods; Jinghai James Xu; Kathy M Yarborough; Jan G Hengstler
Journal:  Arch Toxicol       Date:  2013-08-23       Impact factor: 5.153

10.  A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells.

Authors:  Ahmed Alrifaiy; Johan Borg; Olof A Lindahl; Kerstin Ramser
Journal:  Biomed Eng Online       Date:  2015-04-18       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.