Literature DB >> 16752582

Intraoperative radiation therapy using mobile electron linear accelerators: report of AAPM Radiation Therapy Committee Task Group No. 72.

A Sam Beddar1, Peter J Biggs, Sha Chang, Gary A Ezzell, Bruce A Faddegon, Frank W Hensley, Michael D Mills.   

Abstract

Intraoperative radiation therapy (IORT) has been customarily performed either in a shielded operating suite located in the operating room (OR) or in a shielded treatment room located within the Department of Radiation Oncology. In both cases, this cancer treatment modality uses stationary linear accelerators. With the development of new technology, mobile linear accelerators have recently become available for IORT. Mobility offers flexibility in treatment location and is leading to a renewed interest in IORT. These mobile accelerator units, which can be transported any day of use to almost any location within a hospital setting, are assembled in a nondedicated environment and used to deliver IORT. Numerous aspects of the design of these new units differ from that of conventional linear accelerators. The scope of this Task Group (TG-72) will focus on items that particularly apply to mobile IORT electron systems. More specifically, the charges to this Task Group are to (i) identify the key differences between stationary and mobile electron linear accelerators used for IORT, (ii) describe and recommend the implementation of an IORT program within the OR environment, (iii) present and discuss radiation protection issues and consequences of working within a nondedicated radiotherapy environment, (iv) describe and recommend the acceptance and machine commissioning of items that are specific to mobile electron linear accelerators, and (v) design and recommend an efficient quality assurance program for mobile systems.

Entities:  

Mesh:

Year:  2006        PMID: 16752582     DOI: 10.1118/1.2194447

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Radiation protection for an intra-operative X-ray device.

Authors:  D J Eaton; R Gonzalez; S Duck; M Keshtgar
Journal:  Br J Radiol       Date:  2011-02-08       Impact factor: 3.039

2.  Monte Carlo-based determination of radiation leakage dose around a dedicated IOERT accelerator.

Authors:  Hamid Reza Baghani; Seyed Rashid Hosseini Aghdam; Mostafa Robatjazi; Seyed Rabi Mahdavi
Journal:  Radiat Environ Biophys       Date:  2019-04-10       Impact factor: 1.925

3.  Total skin electron irradiation-The technique where the electron beams are still irreplaceable.

Authors:  Tomasz Piotrowski
Journal:  Rep Pract Oncol Radiother       Date:  2013-12-14

4.  Comparing the performance of some dedicated radioprotection disks in breast intraoperative electron radiotherapy: a Monte Carlo study.

Authors:  Hamid Reza Baghani; Mostafa Robatjazi; Seyed Rabi Mahdavi
Journal:  Radiat Environ Biophys       Date:  2020-04-06       Impact factor: 1.925

5.  Analysis of the long-term stability of the output of electron beams generated by the Novac11™ IORT accelerator.

Authors:  Michał Bijok; Ewelina Gruszczynska; Adam Kowalczyk; Katarzyna Sikorska; Agnieszka Walewska; Pawel F Kukolowicz
Journal:  Rep Pract Oncol Radiother       Date:  2018-08-13

6.  Attenuation measurements show that the presence of a TachoSil surgical patch will not compromise target irradiation in intra-operative electron radiation therapy or high-dose-rate brachytherapy.

Authors:  Sandra Sarmento; Filipa Costa; Alexandre Pereira; Joana Lencart; Anabela Dias; Luís Cunha; Olga Sousa; José Pedro Silva; Lúcio Santos
Journal:  Radiat Oncol       Date:  2015-01-09       Impact factor: 3.481

7.  In vivo dosimetry and shielding disk alignment verification by EBT3 GAFCHROMIC film in breast IOERT treatment.

Authors:  Mara Severgnini; Mario de Denaro; Marina Bortul; Cristiana Vidali; Aulo Beorchia
Journal:  J Appl Clin Med Phys       Date:  2014-01-08       Impact factor: 2.102

8.  Commissioning, clinical implementation, and performance of the Mobetron 2000 for intraoperative radiation therapy.

Authors:  Landon S Wootton; Juergen Meyer; Edward Kim; Mark Phillips
Journal:  J Appl Clin Med Phys       Date:  2017-01       Impact factor: 2.102

9.  Safety, effectiveness and economic evaluation of intra-operative radiation therapy: a systematic review.

Authors:  Farshad Najafipour; Pejman Hamouzadeh; Jalal Arabloo; Mohammadreza Mobinizadeh; Amir Norouzi
Journal:  Med J Islam Repub Iran       Date:  2015-09-07

10.  Dose consumption for quality assurance and maintenance at a dedicated IORT accelerator.

Authors:  Frank W Hensley
Journal:  J Appl Clin Med Phys       Date:  2009-10-27       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.