Temporal subtraction in chest radiography: automated assessment of registration accuracy.

Samuel G Armato1, Devang J Doshi, Roger Engelmann, Charles L Croteau, Heber MacMahon.   

Abstract

Radiologists routinely compare multiple chest radiographs acquired from the same patient over time to more completely understand changes in anatomy and pathology. While such comparisons are achieved conventionally through a side-by-side display of images, image registration techniques have been developed to combine information from two separate radiographic images through construction of a "temporal subtraction image." Although temporal subtraction images provide a powerful mechanism for the enhanced visualization of subtle change, errors in the clinical evaluation of these images may arise from misregistration artifacts that can mimic or obscure pathologic change. We have developed a computerized method for the automated assessment of registration accuracy as demonstrated in temporal subtraction images created from radiographic chest image pairs. The registration accuracy of 150 temporal subtraction images constructed from the computed radiography images of 72 patients was rated manually using a five-point scale ranging from "5-excellent" to "1-poor;" ratings of 3, 4, or 5 reflected clinically acceptable subtraction images, and ratings of 1 or 2 reflected clinically unacceptable images. Gray-level histogram-based features and texture measures are computed at multiple spatial scales within a "lung mask" region that encompasses both lungs in the temporal subtraction images. A subset of these features is merged through a linear discriminant classifier. With a leave-one-out-by-patient training/testing paradigm, the automated method attained an A(z) value of 0.92 in distinguishing between temporal subtraction images that demonstrated clinically acceptable and clinically unacceptable registration accuracy. A second linear discriminant classifier yielded an A(z) value of 0.82 based on a feature subset selected from an independent database of digitized film images. These methods are expected to advance the clinical utility of temporal subtraction images for chest radiography.

Entities:  

Mesh:

Year:  2006        PMID: 16752558     DOI: 10.1118/1.2184441

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  1 in total

1.  Deformable image registration for temporal subtraction of chest radiographs.

Authors:  Min Li; Edward Castillo; Hong-Yan Luo; Xiao-Lin Zheng; Richard Castillo; Dmitriy Meshkov; Thomas Guerrero
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-07       Impact factor: 2.924

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.