Literature DB >> 16752241

Reliability of an automatic ultrasound system in the post partum period in measuring urinary retention.

Adriana F M Van Os1, Paul J Q Van der Linden.   

Abstract

BACKGROUND: Urinary retention in the post partum period may lead to short- and long-term complications.
OBJECTIVE: To investigate the reliability of an automatic ultrasound system to measure the volume of the bladder post partum.
METHODS: About 85 women, who delivered vaginally were observed 6 hr post partum. When the bladder volume measured by BladderScan BVI 3000 was more than 300 ml, it was compared with the bladder volume measured by catheterization.
RESULTS: Ten additional catheterizations were performed by using BladderScan BVI 3000, when compared with the number of estimated cathetharizations based on clinical indications. Eight women had a residual volume of more than 300 ml, of whom two got an indwelling catheter. Using Bland-Altman methods, there was no significant difference in volumes measured by BladderScan BVI 3000 or by catheterization. Also, there was no significant difference between two observers.
CONCLUSION: The BladderScan BVI 3000 is a reliable and non-invasive method to recognize urinary retention in the post partum period.

Entities:  

Mesh:

Year:  2006        PMID: 16752241     DOI: 10.1080/00016340600606992

Source DB:  PubMed          Journal:  Acta Obstet Gynecol Scand        ISSN: 0001-6349            Impact factor:   3.636


  5 in total

Review 1.  Postpartum urinary retention: a systematic review of adverse effects and management.

Authors:  F E M Mulder; R A Hakvoort; M A Schoffelmeer; J Limpens; J A M Van der Post; J P W R Roovers
Journal:  Int Urogynecol J       Date:  2014-05-20       Impact factor: 2.894

2.  Validity of bladder volume measurement by ultrasound in women postpartum.

Authors:  Josefine Tangen Jensen; Niels Klarskov; Jeannet Lauenborg
Journal:  Int Urogynecol J       Date:  2019-07-05       Impact factor: 2.894

3.  Accuracy of postvoid residual volumes after vaginal delivery: a prospective equivalence study to compare an automatic scanning device with transurethral catheterization.

Authors:  Femke E M Mulder; Sytske van der Velde; Fraukje Pol; Marjolein Bos; Jules Schagen van Leeuwen; Viviane Dietz; Robert A Hakvoort; Jan-Paul W R Roovers
Journal:  Int Urogynecol J       Date:  2018-06-27       Impact factor: 2.894

4.  Three-dimensional bladder ultrasonography with the BladderScan® overestimates post void residual one week after delivery.

Authors:  Simone Salimans; Jolien Govaerts; Natasja de Jong; Jeroen van Bavel; Leonie Speksnijder
Journal:  Eur J Obstet Gynecol Reprod Biol X       Date:  2019-05-14

5.  Delivery-related risk factors for covert postpartum urinary retention after vaginal delivery.

Authors:  Femke E M Mulder; Katrien Oude Rengerink; Joris A M van der Post; Robert A Hakvoort; Jan-Paul W R Roovers
Journal:  Int Urogynecol J       Date:  2015-07-30       Impact factor: 2.894

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.