PURPOSE: To test the hypothesis that intra- and interreader reproducibility for measuring the lipid-rich necrotic core (LR-NC) size is significantly improved with gadolinium (Gd) contrast-enhanced magnetic resonance imaging (CEMRI) compared to non-CEMRI. MATERIALS AND METHODS: Thirty-seven individuals with >50% carotid artery stenosis underwent carotid MRI at 1.5T (pre- and postcontrast T1-weighted (T1W), T2-weighted (T2W), proton density-weighted (PDW), and three-dimensional time-of-flight (TOF) sequences). Two independent readers measured the mean area of the LR-NC from the precontrast images only, followed by a second measurement using the additional postcontrast images. One reader repeated the measurements after an interval of five months. Intra- and interreader reproducibility was analyzed by means of the intraclass correlation coefficient (ICC), coefficient of variation (CV), and standard deviation (SD). RESULTS: The CV decreased from 33.7% to 8.8% for intrareader measurements of the LR-NC, and from 33.5% to 17.6% for interreader measurements. The SD was significantly smaller with CEMRI than with non-CEMRI (P = 0.003 and P = 0.006, respectively). The ICC increased from 0.94 to 0.99 and from 0.85 to 0.93 for the intra- and interreader measurements, respectively. CONCLUSION: Reader reproducibility for in vivo MRI quantification of LR-NC size is significantly improved by the addition of Gd contrast in individuals with >50% carotid stenosis. (c) 2006 Wiley-Liss, Inc.
PURPOSE: To test the hypothesis that intra- and interreader reproducibility for measuring the lipid-rich necrotic core (LR-NC) size is significantly improved with gadolinium (Gd) contrast-enhanced magnetic resonance imaging (CEMRI) compared to non-CEMRI. MATERIALS AND METHODS: Thirty-seven individuals with >50% carotid artery stenosis underwent carotid MRI at 1.5T (pre- and postcontrast T1-weighted (T1W), T2-weighted (T2W), proton density-weighted (PDW), and three-dimensional time-of-flight (TOF) sequences). Two independent readers measured the mean area of the LR-NC from the precontrast images only, followed by a second measurement using the additional postcontrast images. One reader repeated the measurements after an interval of five months. Intra- and interreader reproducibility was analyzed by means of the intraclass correlation coefficient (ICC), coefficient of variation (CV), and standard deviation (SD). RESULTS: The CV decreased from 33.7% to 8.8% for intrareader measurements of the LR-NC, and from 33.5% to 17.6% for interreader measurements. The SD was significantly smaller with CEMRI than with non-CEMRI (P = 0.003 and P = 0.006, respectively). The ICC increased from 0.94 to 0.99 and from 0.85 to 0.93 for the intra- and interreader measurements, respectively. CONCLUSION: Reader reproducibility for in vivo MRI quantification of LR-NC size is significantly improved by the addition of Gd contrast in individuals with >50% carotid stenosis. (c) 2006 Wiley-Liss, Inc.
Authors: Li Dong; Williams S Kerwin; Huijun Chen; Baocheng Chu; Hunter R Underhill; Moni Blazej Neradilek; Thomas S Hatsukami; Chun Yuan; Xue-Qiao Zhao Journal: Radiology Date: 2011-04-14 Impact factor: 11.105
Authors: R Kannan Mutharasan; C Shad Thaxton; Jarett Berry; Martha L Daviglus; Chun Yuan; Jie Sun; Colby Ayers; Donald M Lloyd-Jones; John T Wilkins Journal: J Lipid Res Date: 2017-01-03 Impact factor: 5.922
Authors: Dongxiang Xu; Daniel S Hippe; Hunter R Underhill; Minako Oikawa-Wakayama; Li Dong; Kiyofumi Yamada; Chun Yuan; Thomas S Hatsukami Journal: JACC Cardiovasc Imaging Date: 2014-03-13
Authors: Baocheng Chu; Marina S Ferguson; Huijun Chen; Daniel S Hippe; William S Kerwin; Gador Canton; Chun Yuan; Thomas S Hatsukami Journal: JACC Cardiovasc Imaging Date: 2009-07
Authors: H R Underhill; C Yuan; V L Yarnykh; B Chu; M Oikawa; L Dong; N L Polissar; G A Garden; S C Cramer; T S Hatsukami Journal: AJNR Am J Neuroradiol Date: 2009-10-15 Impact factor: 3.825
Authors: Venkatesh Mani; Paul Muntner; Samuel S Gidding; Silvia H Aguiar; Hamza El Aidi; Karen B Weinshelbaum; Hiroaki Taniguchi; Rob van der Geest; Johan H C Reiber; Sameer Bansilal; Michael Farkouh; Valentin Fuster; John E Postley; Mark Woodward; Zahi A Fayad Journal: J Cardiovasc Magn Reson Date: 2009-04-24 Impact factor: 5.364
Authors: Tobias Saam; Jose G Raya; Clemens C Cyran; Katja Bochmann; Georgios Meimarakis; Olaf Dietrich; Dirk A Clevert; Ute Frey; Chun Yuan; Thomas S Hatsukami; Abe Werf; Maximilian F Reiser; Konstantin Nikolaou Journal: J Cardiovasc Magn Reson Date: 2009-10-27 Impact factor: 5.364
Authors: Li Dong; William S Kerwin; Marina S Ferguson; Rui Li; Jinnan Wang; Huijun Chen; Gador Canton; Thomas S Hatsukami; Chun Yuan Journal: J Cardiovasc Magn Reson Date: 2009-12-15 Impact factor: 5.364