Literature DB >> 16736451

Efficient and highly reproducible capillary electrophoresis-mass spectrometry of peptides using Polybrene-poly(vinyl sulfonate)-coated capillaries.

Jonatan R Catai1, Javier Sastre Toraño, Gerhardus J de Jong, Govert W Somsen.   

Abstract

The potential of capillaries noncovalently coated with a bilayer of oppositely charged polymers for the analysis of peptides by CE-MS was investigated. Bilayer coatings were produced by subsequently rinsing fused-silica capillaries with a solution of Polybrene (PB) and poly(vinyl sulfonate) (PVS). The PB-PVS coating showed to be fully compatible with MS detection causing no ionization suppression or background signals. The bilayer coating provided a considerable EOF at low pH, thereby facilitating the fast separation of peptides using a BGE of formic acid (pH 2.5). Under optimized CE-MS conditions, for enkephalin peptides high separation efficiencies were obtained with plate numbers in the range of 300,000-500,000. It is demonstrated that both the cancellation of the hydrodynamic capillary flow induced by the nebulizer gas and a sufficiently high-data acquisition rate are crucial for achieving these efficiencies. The overall performance of the CE-MS system using PB-PVS-coated capillaries was evaluated by the analysis of a tryptic digest of cytochrome c. The system provided an efficient separation of the peptide mixture, which could be effectively monitored by MS/MS detection allowing identification of at least 13 peptides within a time interval of 1.5 min. In addition, the PB-PVS coating proved to be very consistent yielding stable CE-MS patterns with highly favorable migration time reproducibilities (RSDs < 1% over a 3-day period).

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16736451     DOI: 10.1002/elps.200500915

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  3 in total

1.  Microfluidic Capillary Electrophoresis-Mass Spectrometry for Analysis of Monosaccharides, Oligosaccharides, and Glycopeptides.

Authors:  Kshitij Khatri; Joshua A Klein; John R Haserick; Deborah R Leon; Catherine E Costello; Mark E McComb; Joseph Zaia
Journal:  Anal Chem       Date:  2017-06-06       Impact factor: 6.986

2.  Capillary electrophoresis-mass spectrometry using noncovalently coated capillaries for the analysis of biopharmaceuticals.

Authors:  R Haselberg; V Brinks; A Hawe; G J de Jong; G W Somsen
Journal:  Anal Bioanal Chem       Date:  2011-02-14       Impact factor: 4.142

Review 3.  Recent developments in CE and CEC of peptides.

Authors:  Václav Kasicka
Journal:  Electrophoresis       Date:  2008-01       Impact factor: 3.535