Literature DB >> 16734100

Tissue Doppler imaging and gradient echo cardiac magnetic resonance imaging in normal cats and cats with hypertrophic cardiomyopathy.

Kristin A MacDonald1, Mark D Kittleson, Tanya Garcia-Nolen, Richard F Larson, Erik R Wisner.   

Abstract

Cats with hypertrophic cardiomyopathy (HCM) often develop diastolic dysfunction, which can lead to development of left congestive heart failure. Tissue Doppler imaging (TDI) echocardiography has emerged as a useful, noninvasive method for assessing diastolic function in cats. Cardiac magnetic resonance imaging (cMRI) has been performed in cats and accurately quantifies left ventricular (LV) mass in normal cats. However, assessment of cardiac function in cats by cMRI has not been performed. Six normal Domestic Shorthair cats and 7 Maine Coon cats with moderate to severe HCM were sedated, and TDI of the lateral mitral annulus was performed. Peak early diastolic velocity (Em) was measured from 5 nonconsecutive beats. Cats were anesthetized with propofol and electrocardiogram-gated gradient echo cMRI was performed during apnea after hyperventilation. Short-axis images of the LV extending from the mitral annulus to the apex were obtained throughout the cardiac cycle. LV mass at end systole and LV volumes throughout the cardiac cycle were quantified according to Simpson's rule. To assess the possible influence of propofol on diastolic function, TDI was performed on the 7 cats with HCM while sedated and then while anesthetized with propofol. Em was significantly lower in cats with HCM than normal cats (6.7 +/- 1.3 cm/s versus 11.6 +/- 1.9 cm/s, P < .001, respectively). There was no difference in the cMRI indices of diastolic function in normal and HCM cats. Propofol did not reduce diastolic function (Em) in cats with HCM but mildly reduced systolic myocardial velocity (S) in Maine Coon cats with HCM that were anesthetized with propofol (P = .87 and P = .03, respectively).

Entities:  

Mesh:

Year:  2006        PMID: 16734100     DOI: 10.1892/0891-6640(2006)20[627:tdiage]2.0.co;2

Source DB:  PubMed          Journal:  J Vet Intern Med        ISSN: 0891-6640            Impact factor:   3.333


  6 in total

1.  Effects of two different anesthetic protocols on cardiac flow measured by two dimensional phase contrast magnetic resonance imaging.

Authors:  Randi Drees; Rebecca A Johnson; Rebecca L Stepien; Alejandro Munoz Del Rio; Christopher J François
Journal:  Vet Radiol Ultrasound       Date:  2014-08-15       Impact factor: 1.363

2.  QUANTITATIVE PLANAR AND VOLUMETRIC CARDIAC MEASUREMENTS USING 64 MDCT AND 3T MRI VS. STANDARD 2D AND M-MODE ECHOCARDIOGRAPHY: DOES ANESTHETIC PROTOCOL MATTER?

Authors:  Randi Drees; Rebecca A Johnson; Rebecca L Stepien; Alejandro Munoz Del Rio; Jimmy H Saunders; Christopher J François
Journal:  Vet Radiol Ultrasound       Date:  2015-06-16       Impact factor: 1.363

3.  Feasibility of radial and circumferential strain analysis using 2D speckle tracking echocardiography in cats.

Authors:  Hiroshi Takano; Tomomi Isogai; Takuma Aoki; Yoshito Wakao; Yoko Fujii
Journal:  J Vet Med Sci       Date:  2014-11-06       Impact factor: 1.267

4.  Platelet activation in cats with hypertrophic cardiomyopathy.

Authors:  F Tablin; T Schumacher; M Pombo; C T Marion; K Huang; J W Norris; K E Jandrey; M D Kittleson
Journal:  J Vet Intern Med       Date:  2014-02-24       Impact factor: 3.333

5.  Assessment of Myocardial Perfusion at Rest and During Stress Using Dynamic First-Pass Contrast-Enhanced Magnetic Resonance Imaging in Healthy Dogs.

Authors:  Henning Richter; Patrick R Kircher; Fabiola B Joerger; Erika Bruellmann; Matthias Dennler
Journal:  Front Vet Sci       Date:  2018-09-04

6.  The Feline Cardiomyopathies: 2. Hypertrophic cardiomyopathy.

Authors:  Mark D Kittleson; Etienne Côté
Journal:  J Feline Med Surg       Date:  2021-11       Impact factor: 2.015

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.