Literature DB >> 16723040

Heliox during mechanical ventilation.

Shekhar T Venkataraman1.   

Abstract

The indications for heliox during mechanical ventilation are lower-airway obstruction, especially with hypercarbia; need to enhance aerosol delivery to lung periphery; and need to facilitate weaning from mechanical ventilation. Certain ventilators perform relatively well with heliox and are not substantially affected by it. It is preferable to connect the heliox to the air inlet of the ventilator, because this results in more consistent delivery of oxygen and tidal volume. When administering heliox, pay close attention and directly monitor the actual tidal volume and fraction of inspired oxygen.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16723040

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  7 in total

1.  A proof-of-concept trial of HELIOX with different fractions of helium in a human study modeling upper airway obstruction.

Authors:  Hubert Truebel; Sandra Wuester; Philip Boehme; Hinnerk Doll; Sven Schmiedl; Jacek Szymanski; Thorsten Langer; Thomas Ostermann; Dirk Cysarz; Petra Thuermann
Journal:  Eur J Appl Physiol       Date:  2019-03-08       Impact factor: 3.078

2.  Acute severe asthma: new approaches to assessment and treatment.

Authors:  Spyros A Papiris; Effrosyni D Manali; Likurgos Kolilekas; Christina Triantafillidou; Iraklis Tsangaris
Journal:  Drugs       Date:  2009       Impact factor: 9.546

3.  Heliox allows for lower minute volume ventilation in an animal model of ventilator-induced lung injury.

Authors:  Charlotte J Beurskens; Hamid Aslami; Friso M de Beer; Margreeth B Vroom; Benedikt Preckel; Janneke Horn; Nicole P Juffermans
Journal:  PLoS One       Date:  2013-10-18       Impact factor: 3.240

4.  Heliox Improves Carbon Dioxide Removal during Lung Protective Mechanical Ventilation.

Authors:  Charlotte J Beurskens; Daniel Brevoord; Wim K Lagrand; Walter M van den Bergh; Margreeth B Vroom; Benedikt Preckel; Janneke Horn; Nicole P Juffermans
Journal:  Crit Care Res Pract       Date:  2014-12-07

5.  Helium-oxygen mixture: clinical applicability in an intensive care unit.

Authors:  Milena Siciliano Nascimento; Érica Santos; Cristiane do Prado
Journal:  Einstein (Sao Paulo)       Date:  2018-11-08

6.  Mechanical ventilation with heliox in an animal model of acute respiratory distress syndrome.

Authors:  Charlotte J Beurskens; Hamid Aslami; Friso M de Beer; Joris Jth Roelofs; Margreeth B Vroom; Nicole P Juffermans
Journal:  Intensive Care Med Exp       Date:  2014-02-06

7.  Effects of heliox and non-invasive neurally adjusted ventilatory assist (NIV-NAVA) in preterm infants.

Authors:  Natalia Neumann-Klimasińska; T Allen Merritt; Jennifer Beck; Izabela Miechowicz; Marta Szymankiewicz-Bręborowicz; Tomasz Szczapa
Journal:  Sci Rep       Date:  2021-08-04       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.