Literature DB >> 16721350

Low complication rate of LISS for femur fractures adjacent to stable hip or knee arthroplasty.

Robert V O'Toole1, Reuben Gobezie, Raymond Hwang, Autumn R Chandler, R Malcolm Smith, Daniel M Estok, Mark S Vrahas.   

Abstract

UNLABELLED: Fractures of the femur after a knee or hip arthroplasty historically have been plagued with high complication rates. The Less Invasive Stabilization System (LISS) has theoretical advantages of improved biomechanics and limited insult to the bone's vascular supply. We theorized that the LISS would have a lower complication rate than historical controls for these fractures. Patients who were treated with a LISS at two Level I trauma centers from July 2001 to July 2003 were prospectively followed up. The inclusion criteria were an acute fracture of the femur treated with a LISS in a patient with a stable ipsilateral total knee prosthesis and/or hip pros- thesis. There were 24 patients in the study group. The injury mechanism was a low-energy fall for all patients. All patients were females with an average age of 79.5 years (range. 64-93 years). Ten patients had ipsilateral hip arthroplasties, nine patients had ipsilateral total knee arthroplasties, and five patients had knee and hip arthroplasties. Followup was at an average of 48 weeks (range, 17-101 weeks). Eighteen of the 19 fractures in the surviving patients with followup healed uneventfully for a complication rate of 5.2%. One fracture was complicated by hardware pullout and was revised to a longer LISS that healed uneventfully. We think our data show that our patients had a low complication rate compared with that of historical controls, and we suggest that the LISS may be an appropriate treatment alternative for femur fractures associated with stable hip or knee prostheses. LEVEL OF EVIDENCE: Therapeutic, Level IV.

Entities:  

Mesh:

Year:  2006        PMID: 16721350     DOI: 10.1097/01.blo.0000223987.59702.17

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  11 in total

1.  Improved stability with intramedullary stem after anterior femoral notching in total knee arthroplasty.

Authors:  A Completo; F Fonseca; C Relvas; A Ramos; J A Simões
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-06-01       Impact factor: 4.342

2.  Periprosthetic fracture around a stable femoral stem treated with locking plate osteosynthesis: distal femoral locking plate alone versus with cerclage cable.

Authors:  Young-Soo Shin; Seung-Beom Han
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-01-16

3.  Repeat LISS treatment for femoral shaft fractures due to hardware failure: a retrospective analysis of eleven cases.

Authors:  Xu Li; Xian Xu; Lin Liu; Qin Shao; Wei Wu
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-09-22

4.  Treatment results of a periprosthetic femoral fracture case series: treatment method for Vancouver type b2 fractures can be customized.

Authors:  Takahiro Niikura; Sang Yang Lee; Yoshitada Sakai; Kotaro Nishida; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Clin Orthop Surg       Date:  2014-05-16

5.  [Minimally invasive treatment of geriatric and osteoporotic femur fractures with polyaxial locking implants (NCB-DF®)].

Authors:  B F El-Zayat; R Zettl; T Efe; A Krüger; F Eisenberg; S Ruchholtz
Journal:  Unfallchirurg       Date:  2012-02       Impact factor: 1.000

6.  [Periprosthetic fractures in patients with rheumatoid arthritis].

Authors:  G Pap; H W Neumann
Journal:  Z Rheumatol       Date:  2007-02       Impact factor: 1.372

7.  [Results and complications in the treatment of periprosthetic femur fractures with a locked plate system].

Authors:  J Pressmar; F Macholz; W Merkert; F Gebhard; U C Liener
Journal:  Unfallchirurg       Date:  2010-03       Impact factor: 1.000

8.  A review of periprosthetic femoral fractures associated with total hip arthroplasty.

Authors:  Daniel Marsland; Simon C Mears
Journal:  Geriatr Orthop Surg Rehabil       Date:  2012-09

9.  Orthogonal femoral plating: a biomechanical study with implications for interprosthetic fractures.

Authors:  D A Auston; F W Werner; R B Simpson
Journal:  Bone Joint Res       Date:  2015-02       Impact factor: 5.853

10.  Results of titanium locking plate and stainless steel cerclage wire combination in femoral fractures.

Authors:  Bilal Farouk El-Zayat; Steffen Ruchholtz; Turgay Efe; Jürgen Paletta; Dimitri Kreslo; Ralph Zettl
Journal:  Indian J Orthop       Date:  2013-09       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.